Installation Guide

URINAL INITIAL SET-UP
1. After urinal is installed, test
for water tightness by pouring
a bucket of water into the open
drain hole of urinal. If no water
leak is detected, caulk around the
urinal, leaving approx. 8” on the
bottom of the urinal uncaulked.
Wipe urinal clean.
TROUBLESHOOTING
PROBLEM CAUSE REMEDY
There is an odor coming 1. ) BlueSeal® is depleted. If odor comes from urinal trap, add BlueSeal®.
from the urinal. 2. ) EcoTrap® is not seated below rim. Push EcoTrap® down below rim.
3. ) Urinal is not connected properly to the drain. If odor comes from below urinal, remove and reset
urinal to wall and drain line.
Also check oor drain if odor comes from here; if so,
add 1 gal of water to oor drain and add 3 oz. of
EverPrime™, our great oor drain sealer.
Trap does not ush/ow. 1. ) The EcoTrap® is full. Replace the EcoTrap® per Maintenance Instructions.
2. ) The drain line is plugged. Remove the EcoTrap® and snake the drainline.
3. ) The system is double trapped. Remove the drain line trap so that only the EcoTrap® is
the trap for the system.
EcoTrap® Principle
a. Urine ows down into the
patented Vertical EcoTra
drain insert.
b. In the EcoTrap® the urine
passes through a oating
layer of BlueSeal® liquid, which
forms a barrier that prevents
sewer vapors from escaping
into the restroom atmosphere.
c. Urine under the barrier layer
overows into the central
tube and runs down into the
conventional drain line.
2. Take supplied EcoTrap® and ll
with water under faucet in sink.
Fill until full or water overows
on bottom.
3. Insert the water lled EcoTrap®
into the urinal drain opening .
IMPORTANT: then press EcoTrap®
by hand below rim.
4. Insert and tighten Portion-Aid
measuring device onto BlueSeal®
quart bottle. Hold bottle upright.
Squeeze bottle to ll Portion-Aid
to 3oz. Then simply pour BlueSeal®
from Portion-Aid into EcoTrap®.
Done!
How it Works!
EcoTrap®
Insert
below rim.
800.244.6364 | www.waterless.com © Waterless Co. Inc. 0117