Instructions / Assembly
17
Limited Product Warranty
The warranty of our product covers defects in materials and workmanship from
the original date of purchase. During the warranty period, we will replace or repair
any part which is deemed to be defective, if the product has not been subjected to
tampering, alteration, lack of regular maintenance or improper use after delivery.
The cost of repair or replacement under those excluded circumstances shall be
borne by the consumer. This limited warranty does not cover the following items:
lters and all other parts or components that require regular replacement as a
result of ordinary usage. This limited warranty only applies if the system is installed,
used, and maintained in compliance with all instructions and requirements
enclosed with the system.
This limited warranty shall only be valid if:
1. The feed water pressure is no less than 14.5 psi and no more than 87 psi.
2. The feed water temperature must be no less than 39
°F
and no more than 100
°F
.
3. The feed water must have a pH between 6.5 and 8.5.
4. Turbidity must be less than 1.0 NTU.
Any information or suggestions with respect to our product concerning applications,
• The System Hasn’t Been Used in a While
a. Deposits in the tubing may block the lter. Before using the system, turn on
the regular tap and allow the water to run for a while. Turn on the ltered water
faucet and ush the system.
• Filtered Water from the Faucet Tastes Like Tap Water
a. Incorrect tubing installation: Make sure the drain tubing is not connected to the
faucet.
b. The lter is expired: Check the lter life indicator to conrm whether the lter
needs to be replaced; if it does, replace it immediately.
• Water Leakage
a. Check all the joints, ttings, and tubing connections to locate the leakage. Make
sure the lter is well installed.
• Loud Sound from the RO System
The sound will not exceed 55 dB, which is a standard level for everyday life (55
dB is tested under standard laboratory conditions and the feed water pressure is
between 14.5 psi and 87 psi). A loud sound may be caused by any of the following:
a. The system is not positioned in a at area. Make sure the system is placed
smoothly without shaking.
b. The system is placed against the cabinet. Do not place the system against the
cabinet. The system may vibrate when it is in operation.
c. The water pressure is unstable. Check and conrm that the water pressure is
between 14.5 psi and 87 psi. The sound will decrease when the water pressure
becomes stable.