Instructions / Assembly

10
sure there are no leaks at the joints, ttings, valves, or tubing connections.
The water will be undrinkable during the ushing process. The water might
appear black at rst.
You will need to do the timekeeping for the 20-minute ushing yourself. Note
that when the system continuously works for over 40 minutes, it will enter
timeout protection mode. The lter indicator light will ash and the system
will not be able to dispense water. Press the power button for 3 seconds. The
lter indicator light will turn off. Then press the power button for 3 seconds.
The system will return to normal.
4. Before turning off the faucet, make sure the ushing is complete and that there
are no leaks in any of the parts.
NOTE:
When the system stops operation for 10 minutes, it will switch to self-ushing
mode. The system will automatically ush for 20 seconds and then switch to
standby mode. After 10 minutes, the system will not automatically ush again.
When the system stops dispensing water for 24 hours, it will switch to self-
ushing mode. The system will automatically ush for 90 seconds and then
switch to standby mode. The timer will reset. After 24 hours, the system will
not automatically ush again.