INSTA L L ATION A N D S E RVICE M A N U A L W ater Filters: 97WB-IF, 97WB-CF and 97WB-AF Rev. 1.0 4343 S.
Table of Contents QUESTIONS? .................................................................................................................. 1 GETTING MAXIMUM EFFICIENCY FROM YOUR APPLIANCE ..................................... 2 INSTALLATION CHECKLIST ........................................................................................... 3 DO'S AND DON’TS ................................................................................................. ........ 4 REFERENCE ILLUSTRATIONS .............
Questions From 8 am to 5 pm EST, use the 800 HelpLine: 1-800-437-8993 The HelpLine is available to help answer questions about specific water problems, appliance installation and operation. When calling the HelpLine, please have this guide and the serial number of your appliance available. Your serial number may be found on top of your valve assembly (See figures 2-3.
How To Get The Maximum Efficiency From Your Appliance 1. Should your electricity be turned off for any reason you must reset the time of day if you programmed your appliance for delayed regeneration. 2. Protect your system from freezing, including drain line. 3. By-pass the appliance when servicing the well, plumbing, or pump. When work is completed, turn on the nearest cold water tap until water runs clear before putting appliance back in service. See figures 4 - 5 - 6. 4. See start-up procedures.
Checklist Before Installation 1. Water Pressure - Not less than 30 psi constant for WaterBoss® filters. 2. WaterBoss® 97WB-AF adjusts low pH water to a neutral, non-corrosive state. WaterBoss® 97WB-CF reduces chlorine taste and odor. WaterBoss® 97WB-IF reduces iron, hydrogen sulfide and iron bacteria. 3. Water Supply Flow Rate - 5 gallons per minute is recommended as minimum. 4. Drain - Drain appliance to floor drain or washer drain.
Do s And Don ts SOME DO'S 1. Do comply with all local plumbing and electrical codes. 2. Do install pressure-reducing valve if inlet pressure exceeds 90 psi. 3. Do install gravity drain on cabinet. See figure 7. 4. Do secure drain line on appliance and at drain outlet. See figure 3. 5. Do allow a minimum of 8 to 10 feet of 3/4” pipe from the outlet of the water filter to the inlet of the water heater. See figure 1. SOME DON’TS 1. Do not install if checklist items are not satisfactory. 2.
Reference Illustrations Figure 1 - Installation Guide Filter Softener See page 27 for the correct installation sequence. Use this diagram as a location and installation guide for your WaterBoss® 97WB-IF , WaterBoss® 97WB-CF, and WaterBoss® WB-ANF, water conditioners. This diagram applies to all types of installations (i.e. basement, slab, crawl space, outside). Bypass Valves.
Reference Illustrations Figure 2 PLUMBING CONNECTIONS S/N 29350185 Figure 3 CONNECTING DRAIN LINE CAUTION! The drain line must not be kinked, crimped or restricted in any way. The drain line should be 1/2" inside diameter and cannot be reduced in size. S/N 29350185 When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Reference Illustrations Figure 4 Bypass Valves Part #93884 for service or bypass. This part may be available through your local hardware store, plumber or call our HelpLine to order. Figure 6 Figure 5 When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Reference Illustrations Figure 7 OVERFLOW CONNECTION Figure 8 PLUGGING IN TRANSFORMER Do not plug transformer into an outlet that is controlled by on/off switch. When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Reference Illustrations Figure 9 ADDING POTASSIUM PERMANGANATE TO THE IRON FILTER. Figure 10 Open lid and add three gallons of water. Slowly add 5 lbs. potas- Wait 15 minutes and sium permanganate and stir press the Regenerate button. with paint paddle.
Cycles Figure 11 Water by-passes your appliance during regeneration to allow iron and sediment to be washed down the drain. After regeneration, WaterBoss® returns to service, providing your home with filtered water. Regeneration cycles*: 1. First up-flow backwash. A rapid up-flow of water flushes out the media bed. 2. Regeneration. Regenerant is drawn out of the brine cabinet and up through the media tank, cleaning the media bed and releasing accumulated iron and hydrogen sulfide. 3. Slow rinse.
Cycles - Iron Filter Only Figure 11 1 First up-flow backwash 4 Second up-flow Cycles - 2 Regenerant Draw 5 Downflow clean 3 Slow Rinse 6 Return to service Carbon & Acid Neutralizing Filters Only Backwash Return To Service 11
Installation And Start-Up Procedures Each WaterBoss® water filter includes water test strips and 8' of drain line and a drain fitting. 1. Placement: Place your WaterBoss® appliance in desired location. Turn off electricity and water supply to water heater. Make sure inlet/outlet and drain connections meet the applicable local codes. Check arrows on valve to be sure water flows in proper direction. See figures 1, 2, & 3. CAUTION: DO NOT PLUMB APPLIANCE IN BACKWARD. 2.
97WB-CF Carbon Filter S tart-Up Procedures Your waterBoss Carbon filter will backwash every one to four days. You select the frequency based on local conditions. You will need to set the time of day and the desired time of regeneration by following the procedure outlined on page 17 of this manual.
97WB-AF Acid Neutralizing Filter S tart-Up Procedures Your WaterBoss Acid Neutralizing Filter may be programmed to regenerate every one or two days. You select the frequency based on local conditions. You will have to set the time of day and the desired time of regeneration by following the procedure outlined on page 17 of this manual.
97WB-IF Iron Filter S tart-Up Procedures Your WaterBoss Iron Filter may be programmed to regenerate every one to fourteen days. You select the frequency based on the amount of iron in the water and the number of people in the household. You will have to set the time of day and the desired time of regeneration by following the procedure outlined on page 17 of this manual. See the WaterBoss Iron Filter Application Chart on page 16.
W aterBoss Iron Filter Application Chart Figure 15 16
Setting The Controller: To ensure that your WaterBoss Filter operates properly, follow the setting instructions below. For the iron filter, refer to the selection chart on page 16. To set the desired frequency of regeneration, or backwash, press and hold the SET button for 3 seconds. When “01” is displayed, release the set button and press and release the change button to set the desired frequency. Press the set button to return to the main screen and the number you selected will be displayed.
Care, Maintenance and Parts Figure 16 Electronics and Cabinet 1 2 3 4 5 6 7 PART# 54306 54324 54513-IF 54513-CF 54513-AF 93245 54303 54305 97506 97509 DESCRIPTION Salt Port Lid Valve Cover Assembly Computer Control Assembly - Iron Filter Computer Control Assembly - Carbon Filter Computer Control Assembly - Acid Neutralizing Filter 12V Transformer/Power Cord Cabinet Support Panel Media Tank, empty with fill plug for IF & AF Media Tank, empty with fill plug for CF only QUANITY 1 1 1 1 1 1 1 1 1 1 When
Care, Maintenance and Parts Figure 17 - Cabinet and Assemblies 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PART# CO700A 93505 93838 93281 93272 93808 90828 95301T-JG 95302T-BWO 93870 93848 93501 93835 90614-5.0 90614-3.
Care, Maintenance and Parts Figure 18 - Injector Assembly When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Care, Maintenance and Parts Figure 19 - I/O Adapter Assembly 1 2 PART# 54313 93838 DESCRIPTION 3/4" IO Adapter “O” Ring 21 QUANITY 1 2
Care, Maintenance and Parts Figure 20 - Drive End Cap Assembly (Iron Filter Only) * * * 90821 95521 * Not available on AF and CF models. When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Care, Maintenance and Parts Figure 21 - Brine Valve Housing Assembly, Iron Filter Only When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Care, Maintenance and Parts Figure 22 - Safety Shutoff Assembly 1 2 3 4 5 6 7 8 9 PART# 54226 * * * * 10700-IF H5785-IF * H4656 54526 *Included with DESCRIPTION Safety Shutoff Valve 3/8” Retainer Sleeve 3/8” Plastic Gripper 3/8” Nut Wrist Pin Float Assembly Air Check Assembly 3/8” Nut 1/2” x 3/8” Sleeve Gripper Set Safety Shutoff Assembly 54226 QUANITY 1 1 1 1 1 1 1 1 1 When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993.
Care, Maintenance and Parts Figure 23 - Fill Plug Assembly 93281 93272 When calling the HelpLine, please have this guide and the serial number available. From 8 am to 5 pm EST, call 1-800-437-8993. Your serial number may be found on top of your valve assembly (See figures 2-3.
Troubleshooting Problem Cause Solution Read-out lights do not glow. Defective circuit board (fig. 10). With 12 VAC present at controller, replace circuit board. Filter stays in regeneration. Cycle numbers remain flashing. Computer control not attached properly. Make sure computer control is pushed all the way onto drive end cap. Foreign object in valve body. Remove foreign objects from valve body. Broken valve assembly. Motor running. Magnet disc not turning (page 22). Repair drive end cap.
Filter Specifications MODEL # 97WB-IF Maximum compensated hardness (grains) Maximum ferrous iron reduction Media type and amounts NA NA 15 ppm NA NA NA 6.3 Greensand .7 cu. ft. Carbon .7 cu. ft. Calcite/Corosex .7 cu. ft. 2.8 oz. Potassium Permanganate per regeneration Backwash only Backwash only 80ºF Maximum water temperature Mineral tank size NA 7 Minimum pH Salt usage (lbs.) / Capacity 97WB-CF 97WB-AF 10.5 X 21” I.D.
Limited Warranty To Whom Warranty is Extended This warranty is issued to the original owner at the original location site and is not transferable to other sites or to subsequent owners of the system. CONSEQUENTIAL OR SECONDARY DAMAGES. ANY IMPLIED WARRANTIES ON THE PRODUCT DESCRIBED IN THIS WARRANTY WILL NOT BE EFFECTIVE AFTER THE EXPIRATION OF THIS WARRANTY.
has these third party listings. UL ® ® In Business Since 1956 ©1998 WaterBoss® P.O.