Technical Specifications
27
Specifications
70 0 9 0 0 9 5 0
Maximum compensated hardness–
g rains/g al (mg /L )
70 (1,200) 9 0 (1,5 4 0) 35 (6 00)
Maximum ferrous iron reduction
1
10 ppm
1
10 ppm
1
0
Minimum pH –standard units 7 7 7
Media ty pe and amounts
S elf C leaning F ilter Media.
S uper F ine Mesh R esin
T otal–0.7 ft
3
(0.02 m
3
)
S elf C leaning F ilter Media.
S uper F ine Mesh R esin
T otal–1 ft
3
(0.03 m
3
)
R edox Media–4 lb (1.8 k g )
A ctiv ated C arb on–0.25 ft
3
(0.007 m
3
)
S uper F ine Mesh R esin–0.7 ft
3
(0.02 m
3
)
T otal: 1 cu. ft. (0.03 m
3
)
S alt
2
– C apacity – W ater– T ime–
pounds g rains g allons minutes
(k g ) (mg /L ) (L )
1 5 ,5 00 11.1 15 :00
(0.5 ) (9 4 ,000) (4 2.0)
1 5 ,6 00 11.1 15 :00
(0.5 ) (9 5 ,8 00) (4 2.0)
1 5 ,5 00 12.3 16 :00
(0.5 ) (9 4 ,000) (4 6 .6 )
S alt
2
– C apacity – W ater– T ime–
pounds g rains g allons minutes
(k g ) (mg /L ) (L )
2.5 10,4 00 13.9 19 :30
(1.1) (178 ,000) (5 2.6 )
3 15 ,4 00 14 .8 21:00
(1.4 ) (26 3,300) (5 6 .0)
2.5 10,4 00 15 .1 19 :30
(1.1) (178 ,000) (5 7.2)
S alt
2
– C apacity – W ater– T ime–
pounds g rains g allons minutes
(k g ) (mg /L ) (L )
6 .5 17,000 22.4 32:00
(2.9 ) (29 1,000) (8 5 .8 )
7.5 28 ,8 00 23.5 33:30
(3.4 ) (4 9 2,5 00) (8 9 .0)
6 .5 17,000 23.9 32:00
(2.9 ) (29 1,000) (9 0.5 )
S alt
2
– C apacity – W ater– T ime–
pounds g rains g allons minutes
(k g ) (mg /L ) (L )
12 22,100 28 .6 4 1:00
(5 .4 ) (377,9 00) (108 .3)
15 36 ,4 00 32 4 6 :30
(6 .8 ) (6 22,4 00) (121)
12 22,100 30.1 4 1:00
(5 .4 ) (377,9 00) (113.9 )
Minimum / Maximum w ater and amb ient
temperature–
$
F (
$
C )
4 0/120 (4 .4 /4 8 .9 ) 4 0/120 (4 .4 /4 8 .9 ) 4 0/120 (4 .4 /4 8 .9 )
Mineral tank siz e–in. (cm)
10.5 I.D . x 19
(26 .7 I.D . x 4 8 .3)
10.5 I.D . x 26
(26 .7 I.D . x 6 6 )
10.5 I.D . x 26
(26 .7 I.D . x 6 6 )
P eak flow rate @ 15 /psi drop (1 b ar) 12 g pm (4 5 .4 L pm) 10 g pm (37.9 L pm) 8 g pm (30 L pm)
P ressure drop at serv ice flow rate of
8 g pm (30.3 L pm)–psi (b ar)
8 (0.6 ) 11 (0.8 ) 15 (1.0)
Maximum flow rate to drain during
reg eneration–b ack w ash g pm (L pm)
2.4 (9 .1) 2.4 (9 .1) 3.0 (11.4 )
W ater pressure–minimum/maximum psi (b ar) 20/120 (1.4 /8 .3) 20/120 (1.4 /8 .3) 20/120 (1.4 /8 .3)
Minimum w ater flow req uired–g pm (L pm) 2.4 (9 .1) 2.4 (9 .1) 3.0 (11.4 )
Maximum chlorine (ppm) 0.0 0.0 3.0
C ontroller ty pe 4 B utton 4 B utton 4 B utton
F req uency of reg eneration D emand D emand D emand
S alt storag e–lb (k g ) 120 lb (5 4 .4 ) 170 lb (77.1) 170 lb (77.1)
H eig ht–in. (cm) 25 .5 (6 4 .8 ) 30.5 (77.5 ) 30.5 (77.5 )
F ootprint–in. (cm) 15 x 19 (38 x 4 8 ) 15 x 19 (38 x 4 8 ) 15 x 19 (38 x 4 8 )
E lectrical rating
12 V A C , 5 0/6 0 H z ,
0.015 k W -hr
12 V A C , 5 0/6 0 H z ,
0.015 k W -hr
12 V A C , 5 0/6 0 H z ,
0.015 k W -hr
P lumb ing connections 1" male (MN P T ) 1" male (MN P T ) 1" male (MN P T )
S hipping w eig ht— approximate–lb (k g ) 8 5 (38 .6 ) 105 (4 7.6 ) 105 (4 7.6 )
1
T he state of W isconsin limits iron reduction claims to 5 ppm.
2
U se clean, w hite pellet or solar salt.
T hese appliances are efficiency rated according to N S F /A N S I 4 4 . T he stated efficiency is v alid only at the specified salt dosag e and 8 g pm (30 L pm).
M o d e l #