Understanding the Controller
Advanced Customer Settings (cont.)
Set Hours Until R egeneration
F. “96 Hours” is now displayed. Press and release the CHANGE button to toggle this on and off. If “96 Hours” is
selected, the appliance will work no more than 4 days without a regeneration. Default is for “96” Hours” to be ON.
Note: If there is iron in your water, select this option.
G. When the desired setting is displayed, press and release the SET button.
Set Gallons or Litres
H. “Gallons X 100” is now displayed. Press and release the CHANGE button to toggle between “Gallons X 100” and
“Litres X 1000”. Choosing “Gallons” sets the controller to English units, and choosing “Litres” sets it to metric
units.
I. When the desired setting is displayed, press and release the SET button.
Set Time Format
J . If “Gallons” were chosen, “12” is now displayed. If “Litres” were chosen, “24” is displayed. Pressing and releasing
the CHANGE button will toggle between “24” and “12”. This controls the selection of a 12-hour (AM/PM) or
24-hour clock. If 24-hour, 00=midnight.
K . When the desired setting is displayed, press and release the SET button.
Set Time
L. “Set Time” and “12” is now displayed. To set the time, press and release the CHANGE button until the correct
time is displayed. Default is 12 PM.
Note: Set the time to the nearest hour.
M. When the desired setting is displayed, press and release the SET button.
Set R egeneration Time
N. “Set Reg. Time” and “02” is now displayed. To set the regeneration time, press and release the CHANGE button
to advance the numerical display. Default is 2 AM.
O. When the desired setting is displayed, press and release the SET button to save the “regen. time” displayed.
P. The appliance has been placed into operation.
Programming Is Now Complete