Instructions / Assembly

2
ELECTRICAL CONNECTION
ELECTROCUTION HAZARD. FIRST DISCONNECT ALL
ELECTRICAL POWER BEFORE SERVICING.
ELECTROCUTION HAZARD. THE WWDPC MUST BE
ELECTRICALLY GROUNDED.
NOTE: The WWDPC will operate on 115 VAC & 230 VAC systems. Its ambient air
temperature rating is 122°F / 50°C.
1. Disconnect power and verify with a volt meter.
2. Determine the pump electrical requirements. If unknown, contact the pump
manufacturer.
3. Select the appropriate wire gauge per local codes and the pump manufacturer’s
recommendation.
INSTALLATION INSTRUCTIONS
Unit is Recommended to be Installed by a Qualified Professional
PLUMBING CONNECTION (1/4" NPT FEMALE SYSTEM CONNECTION)
1. Select a location for the WWDPC. The WWDPC should be mounted near the
pressure tank or pump, depending upon the installation
LOCATE THE WWDPC FOLLOWING ALL LOCAL CODES. DO NOT
LOCATE THE UNIT WHERE IT CAN BE AFFECTED BY FLOODING.
2. You may assemble the WWDPC to a “Tank Tee” or “Tank Cross” (Figure 1) or adapt
the unit to an in-line pipe fitting (Figure 2). Use Teflon sealing tape or pipe sealant.
Tighten the WWDPC using the wrench flats provided on the bottom connection. DO
NOT EXCEED 15LB./FT. of torque.
Note: Do not allow pipe sealant or other contaminants to enter the small port in the
WWDPC connection.
Note: A mechanical pressure gauge is not required. Use the appropriate plug to block
any unused ports.
Drain
Valve
Relief Valve
1/4" NPT Female
System Connection
INSTALLATION ON TYPICAL TANK TEE
Fig. 1
Pipe Nipple Plug
WWDPC
GENERAL IN-LINE INSTALLATION
Tee
Adapt as necessary
Pipe Nipple
Relief Valve
WWDPC
Fig. 2
1/4" NPT Female
System Connection