Troubleshooting guide

START-UP INSTRUCTIONS:
11
• After installation is complete, rotate bypass handles to bypass mode (see Fig.2 on page 4).
• Turn on water and check for leaks.
• Fully open a cold water faucet — preferably a laundry sink or bathtub without an aerator.
• Allow water to run until clear to rid pipes of debris which may have occurred during installation.
System regeneration sequence is in the following order. Some sequence differences may be noticed
depending upon local conditions. (If it is desired to change this sequence, please refer to the Dealer Manual
or contact the manufacturer.)
Sequencing for Various Filters (Medias)
:
Acid Optional Acid Neutralizing Impression Sulfur &
Neutralizer Sequencing Iron Air Systems
1. Backwash 1. Backwash 4. Backwash 7. Return to service 1. Backwash
2. Rinse 2. Filtering 5. Filtering 2. Air draw
3. Return to service 3. Rapid rinse 6. Rapid rinse 3. Return to service
The system is now ready for filling with water and for testing.
1. Place the bypass valve into the bypass mode (Fig. 2 on page 4).
2. Press and hold the
REGEN button until the motor starts. Release button. Put the valve into “BACKWASH”
position. Unplug the transformer so that the valve will not cycle to the next position. Open the inlet handle
of the bypass valve very slightly allowing water to fill the tank slowly in order to expel air.
CAUTION: If water flows too rapidly, there will be a loss of media to the
drain. Some medias such as carbon and Filter Z should not be
backwashed immediately for extended periods of time. These
medias need to “soak” in the water for a 24-hour period prior
to full backwash conditions.
3. When the water is flowing steadily to the drain without the presence of air, slowly open the inlet valve.
Restore power and momentarily press the
REGEN button to advance the control to the “RINSE” position.
4. With the bypass still in the diagnostic mode (Fig. 3 on page 4), there should be a rapid flow to the
drain. Unplug the transformer to keep the valve in the “RINSE” position. Allow water to run until steady,
clear and without air.
Note: Carbon filters, Filter Z filters and Impression Air Systems may require a longer rinse period to rinse
the media of excess particles. Some “color throw” can be expected. Run water until clear.
5. Restore power, press
REGEN button in sequence until display returns to “TIME.” Place bypass valve in the
normal operating mode (Fig. 1 on page 4) by opening the outlet bypass handle.
6. Go to laundry tub or bathtub faucet, preferable a faucet without an aerator, and turn on cold water. Let the
water run. Note the color of water coming from faucet. If discolored, let water run until clear. If severely
discolored, place unit into rinse position (step 4) and run water to the system’s drain until clear.
Note: At no time should there by large particles of media noticed at faucet or laundry tub. If this is seen,
immediately shut off water and bypass system, as this could be an indication of a distributor failure.
Contact manufacturer or distributor for assistance.
7. For IMS and IMB filters, place unit into regeneration again and allow to complete cycle. Upon
completion, unit will have an air charge and will delivery treated water.