Troubleshooting guide

10
3. MANUAL REGENERATION: Sometimes there is a need to
regenerate before the control valve calls for it. This may be
needed if a period of heavy water use is anticipated or when
the system has been operated without salt.
• To initiate a manual regeneration at the next
preset regeneration time, press and release
REGEN. The words “REGEN TODAY” will flash
on the display to indicate that the system will
regenerate at the next regeneration time (set in
Programming, steps 4 and 5). If you pressed the
REGEN button in error, pressing the button again
will cancel the command.
• To initiate a manual regeneration immediately, press and hold
the
REGEN button for three seconds. The system will begin to
regenerate immediately. This command cannot be cancelled.
Once a manual regeneration is initiated, the unit will go into the BACKWASH position and subsequent
positions thereafter (see Start Up Instructions for regeneration sequence), the water filter will deliver water,
but it will be untreated.
4. POWER LOSS AND BATTERY REPLACEMENT:
The AC transformer comes with a 15 foot power cord and is
designed for use with the control valve; the transformer should
only be used in a dry location.
In the event of a power outage that is less than 24 hours, the
control valve will remember all settings and time of day. After 24
hours, the only item that needs to be reset is the time of day and
will be indicated by the time of day flashing. All other settings are
permanently stored in the nonvolatile memory.
If a power loss occurs that is less than 24 hours and the time of
day flashes, this indicates that the battery is depleted. The time of
day should be reset and the non-rechargeable battery should be
replaced. The battery is a 3 Volt Lithium Coin Cell type 2032 and
is readily available at most stores. To access battery location,
remove front cover (see diagram on page 14 for battery location).
5. ERROR MESSAGE: If the word “ERROR” and a number are
alternately flashing on the display record the number and
contact the dealer for help. This indicates that the control valve
was not able to function properly.
MANUAL REGENERATION
BATTERY REPLACEMENT
ERROR