Troubleshooting guide

1900 Prospect Court • Appleton, WI 54914
Phone: 920-739-9401 • Fax: 920-739-9406
MANUAL REGENERATION
NOTE: For softeners, if brine tank does
not contain salt, fill with salt and wait
at least two hours before regeneration.
If you need to initiate a manual
regeneration, either immediately, or the
same night at the preprogrammed time
for regeneration (typically 2:00 AM),
complete the following steps.
For Immediate Regeneration:
Press and hold regen until valve motor
starts (typically 3 seconds).
For Regeneration the same night:
Press and release regen (notice that flashing “REGEN TODAY”
ERROR
If the display toggles between “Error”
and an error code (i.e. a number), call
a service technician and report the
error code.
BYPASS VALVE OPERATION
To shut off water to the system, position arrow handles as shown in
the bypass operation diagram below. If your valve doesn’t look like
the diagram below, contact your service technician for instructions
on how to shut off water.
REGEN TODAY MON
GPM
2:408
PM
REGEN TODAY and TIME OF DAY
will flash alternately if a regeneration
is expected tonight.
NORMAL OPERATION BYPASS OPERATION
ADJUST HARDNESS, DAYS BETWEEN REGENERATION, TIME OF REGENERATION AND ALARM BUZZER
For initial set-up or to make adjustments, please complete the following steps.
QUICK REFERENCE GUIDE:
GENERAL OPERATION
When the system is operating, one of four displays will be shown:
time of day/gpm, flow rate, capacity remaining or days to a regen.
Pressing next will toggle between the three choices.
TO SET TIME OF DAY
In the event of a prolonged power outage, time of day flashes,
indicating that this needs to be reset. All other information will be
stored in memory no matter how long the power outage.
1. Accessed by pressing set clock
2. Adjust hours with + and buttons, AM/PM toggles at 12
3. Press next
4. Adjust minutes with + and buttons
5. Press next
6. Adjust current day with + and buttons
7. Press next to complete and return to normal operation
1. Accessed by pressing next and + button simultaneously
2. Adjust hardness using + and buttons
3. Press next
4. Adjust days between regenerations using + and buttons
5. Press next
6. Adjust time of regeneration hour with + and buttons,
AM/PM toggles at 12.
7. Press next
8. Adjust time of regeneration minutes with + and buttons
9. Press next
10. Turn alarm buzzer ON or OFF with + and buttons
11. Press next to complete and return to normal operation.
TIME OF DAY MON
GPM
2:408
PM
FLOW RATE
GPM
8.0
CAPACITY REMAINING
GPM GAL
1600
8
DAYS TO A REGEN
GPM
3
8
TIME OF DAY MON
GPM
2:408
PM
FLOW RATE
GPM
8.0
CAPACITY REMAINING
GPM GAL
1600
8
DAYS TO A REGEN
GPM
3
8
CURRENT DAY
SET
MON
TIME MINUTES
SET
TIME HOUR
SET
2:00
AM
CURRENT DAY
SET
MON
TIME MINUTES
SET
TIME HOUR
SET
2:00
AM
ALARM BUZZER
SET
ON
REGEN TIME MINUTES
SET
2:00
AM
REGEN TIME HOUR
SET
2:00
AM
DAYS BETWEEN REGEN
SET
6
WATER HARDNESS
SET
20
GR
ALARM BUZZER
SET
ON
REGEN TIME MINUTES
SET
2:00
AM
REGEN TIME HOUR
SET
2:00
AM
DAYS BETWEEN REGEN
SET
6
WATER HARDNESS
SET
20
GR