Troubleshooting guide

26
SPECIFICATIONS:
1
All Sanitizer Plus water conditioners are pre-factory set at medium salting. Note: influent waters must be at least 3 GPG
hardness and 80 TDS. A calcite or corsex unit may be needed for correct operation.
2
Combined iron and manganese removal varies depending on the form of iron, manganese, pH and other local
conditions. On waters that are pre-chlorinated or where other pre-oxidation occurs, precipitated metal oxides may form
that are too fine to be filtered.
3
The pH listed is the minimum for the influent water.
4
Optimum pH adjustment occurs at 3.0 gpm or less at maximum salt settings. Higher flow rates will produce less pH
adjusted water.
5
Unit not tested for capacity at these flow rates. Water quality may vary.
MODEL ASP1-1044 ASP1-1054 ASP1-1354 ASP2-1044 ASP2-1054 ASP2-1354
1
Capacity: Maximum
11,800 @ 12.4 22,600 @ 15.9 36,900 @ 21.2 20,300 @ 12.4 34,800@ 15.9 60,300 @ 26.5
(Grains/Lbs. NaCI) Medium
11,400 @ 9.3 20,700 @ 12.4 33,600 @ 15.9 19,100 @ 9.3 32,000 @ 12.4 48,300 @ 15.9
Minimum
7,300 @ 3.2 16,400 @ 6.1 28,300 @ 9.5 11,100 @ 3.2 22,900 @ 6.1 28,200 @ 9.3
Amount of Media (Cu. Ft.)
1.0 1.5 2.5 1.0 1.5 2.5
Maximum Water Hardness (GPG)
20 30 40 40 60 80
2
Maximum Iron and Manganese (PPM)
8.0 10.0 15.0 8.0 10.0 15.0
3
Minimum pH
6.5 6.0 6.0 7.0 7.0 7.0
4
Total pH Adjusted Water
510 510 863 NA NA NA
5
Peak Flow Rate (GPM @ P-PSI)
19.0 @ 8.3 17.0 @ 7.8 19.0 @ 7.6 19.0 @ 9.3 17.0 @ 9.1 19.0 @ 8.6
Continuous Flow Rate (GPM @ P-PSI)
9.0 @ 2.4 9.0 @ 2.8 9.0 @ 2.7 9.0 @ 3.0 8.0 @ 3.7 9.0 @ 2.8
Water Pressure Range (PSI) 25-100 25-100 25-100 25-100 25-100 25-100
Water Temp. (ºF) 33-100 33-100 33-100 33-100 33-100 33-100
Electrical Requirements (volts-hertz) 110-50/60 110-50/60 110-50/60 110-50/60 110-50/60 110-50/60
Pipe Size 1” 1” 1” 1” 1” 1”
Total Dimensions: Media Tank
10”W x 52”H 10”W x 62”H 13”W x 62”H 10”W x 52”H 10”W x 62”H 13”W x 62”H
Brine Tank
18”W x 33”H 18”W x 33”H 18”W x 40”H 18”W x 33”H 18”W x 33”H 18”W x 40”H
MODEL
ASPR-1044 ASPR-1054 ASPR-1354 ASPR-844
1
Capacity: Maximum
32,000 @ 15.0 48,800 @ 21.0 72,800 @ 24.0 25,600 @ 9.0
(Grains/Lbs. NaCI) Medium
28,400 @ 9.0 44,400 @ 15.0 64,200 @ 18.0 21,600 @ 6.0
Minimum
23,600 @ 6.0 35,400 @ 9.0 53,000 @ 12.0 15,600 @ 3.0
Amount of Media (Cu. Ft.)
1.0 1.5 2.5 0.85
Maximum Water Hardness (GPG)
75 100 100 50
2
Maximum Iron and Manganese (PPM)
1.0 1.0 1.0 1.0
3
Minimum pH
7.0 7.0 7.0 7.0
5
Peak Flow Rate (GPM @ P-PSI)
17.1 @ 15.0 15.2 @ 15.0 20.3 @ 15.0 11.8 @ 15.0
Continuous Flow Rate (GPM @ P-PSI)
5.0 @ 2.8 5.0 @ 4.0 5.0 @ 2.6 5.0 @ 5.3
Water Pressure Range (PSI) 25-100 25-100 25-100 25-100
Water Temp. (ºF) 33-100 33-100 33-100 33-100
Electrical Requirements (volts-hertz) 110-50/60 110-50/60 110-50/60 110-50/60
Pipe Size 1” 1” 1” 1”
Total Dimensions: Media Tank
10”W x 52”H 10”W x 62”H 13”W x 62”H 8”W x 52”H
Brine Tank
18”W x 33”H 18”W x 33”H 18”W x 40”H 18”W x 33”H
MODEL ASP1-1044 ASP1-1054 ASP1-1354 ASP2-1044 ASP2-1054 ASP2-1354 ASPR-1044 ASPR-1054 ASPR-1354 ASPR-844
MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL. MIN. GAL.
Brine Refill 5:51 3 9:53 5 11:53 6 5:51 3 9:53 5 11:53 6 5:51 3 9:53 5 11:53 6 3:51 2
Backwash 12 42 12 48 12 84 12 36 12 42 12 60 8 22 8 22 10 32 6 10
Brine & Rinse 72 29 90 36 90 72 72 29 90 36 90 72 60 24 90 36 90 47 40 16
Rapid Rinse 4 14 4 16 4 28 4 12 4 14 4 20 4 11 4 11 4 13 4 7
Total 94 88 116 105 118 190 94 80 116 97 118 158 78 60 112 74 116 98 54 35