Installation Instructions & Owner’s Manual Impression Plus Series Metered Water Softeners ®
TABLE OF CONTENTS Preinstallation Instructions for Dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Bypass Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Programming Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8 Operating Displays and Instructions . . . . . . . . . . . . . . .
PREINSTALLATION INSTRUCTIONS FOR DEALERS: The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation. For the installer, the following must be used: • Program Installer Settings: Hardness, Day Override (preset to 12 days), and Time of Regeneration (preset to 2 a.m.
1. NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener. During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig. 1). 2. BYPASS POSITION: The inlet and outlet handles point to the center of the bypass.
INSTALLATION: GENERAL INSTALLATION & SERVICE WARNINGS The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone lubricant may be used on black “O” Rings, but is not necessary.
. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. Make provisions to bypass outside hydrant and cold hard water lines at this time. Install an inlet shutoff valve and plumb to the unit’s bypass valve inlet located at the right rear as you face the unit. There are a variety of installation fittings available. They are listed under Installation Fitting Assemblies, page 22-23.
PROGRAMMING PROCEDURES: 1. Set time of day: Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time should be reset. STEP 1 – Press SET CLOCK. STEP 2 – CURRENT TIME (HOUR): Set the hour of the day using + or — buttons. AM/PM toggles after 12. Press NEXT to go to step 3. STEP 3 – CURRENT TIME (MINUTES): Set the minutes using + or — buttons.
2. Programming cont’d: STEP 4 – REGENERATION HOUR: The manufacturer has factory set 2:00 A.M. as the default. This is the hour of day for regeneration and can be reset by using + or — buttons. “AM/PM” toggles after 12. The default time is 2:00 a.m. (recommended for a normal household). Press NEXT to go to step 5. Press REGEN if you need to return to the previous step. STEP 5 – REGENERATION MINUTES: Set the minutes using + or — buttons. Press NEXT to exit installer programming.
3. MANUAL REGENERATION: Sometimes there is a need to regenerate before the control valve calls for it. This may be needed if a period of heavy water use is anticipated or when the system has been operated without salt. • To initiate a manual regeneration at the next preset regeneration time, press and release REGEN. The words “REGEN TODAY” will flash on the display to indicate that the system will regenerate at the next regeneration time (set in Programming, steps 4 and 5).
5. ERROR MESSAGE: If the word “ERROR” and a number are alternately flashing on the display record the number and contact the dealer for help. This indicates that the control valve was not able to function properly. ERROR 6. BRINE TANK MAINTENANCE AND SALT: Refill the brine tank as necessary, making sure at least 1/3 of the brine tank is full at all times. Without proper salt levels, the water softener may not operate properly.
START-UP INSTRUCTIONS: • • • • After installation is complete, rotate bypass handles to bypass mode (see Fig.2 on page 4). Turn on water and check for leaks. Fully open a cold water faucet — preferably a laundry sink or bathtub without an aerator. Allow water to run until clear to rid pipes of debris which may have occurred during installation. System regeneration sequence is in the following order. (If it is desired to change this sequence, please refer to the Dealer Manual or contact the manufacturer.
TROUBLESHOOTING GUIDE: PROBLEM Timer does not display time of day Timer does not display correct time of day or time of day flashes No softening/ filtering display when water is flowing CAUSE CORRECTION A. transformer unplugged A. reconnect transformer B. no power at outlet B. repair or use working outlet C. defective transformer C. replace transformer D. defective PC board D. replace PC board A. outlet is on a switch A. use unswitched outlet B. power outage B.
PROBLEM Valve does not regenerate automatically when REGEN button is pressed Valve does not regenerate automatically but does when REGEN button is pressed CAUSE CORRECTION A. transformer unplugged A. connect transformer and PC board power B. no power at outlet B. restore power C. broken drive gear or drive cap assembly C. replace gear or drive cap assembly D. defective PC board D. replace board A. bypass valve not in normal operating mode A. see bypass diagrams on page 4 B.
REPLACEMENT PARTS: FRONT COVER AND DRIVE ASSEMBLY Item No. 1 Part No. Description Qty.
REPLACEMENT PARTS: 1 13 14 5 4 7 9 3 8 2 10 11 12 PISTON ASSEMBLY Item No. Part No. Description Qty. CV3005 1" spacer stack assembly 1 CV3430 1.25" spacer stack assembly 1 2 CV3004 Drive cap assembly 1 3 CV3135 O-ring 228 1 CV3011 1" piston assembly downflow 1 1" piston assembly upflow 1 1.
REPLACEMENT PARTS: BYPASS VALVE Item No. Part No. 1 2 3 4 5 6 7 8 9 10 CV3151 CV3150 CV3105 CV3145 CV3146 CV3147 CV3148 CV3152 CV3155 CV3156 Description Qty.
REPLACEMENT PARTS: INJECTOR ASSEMBLIES Item No. Part No.
REPLACEMENT PARTS: DRAIN LINE ASSEMBLY 3/4" Item No. Part No. 1 CH4615 2 CPKP10TS8-BULK 3 CV3192 4 CV3158-01 5 CV3163 6 7 8 CV3159-01 Description Elbow locking clip 1 Optional insert, 5/8" tube 1 Optional nut, 3/4" drain elbow 1 Drain elbow, 3/4" NPT with O-ring 1 O-ring 019 1 DLFC retainer assembly 1 CV3162-007 0.7 DLFC for 3/4" elbow CV3162-010 1.0 DLFC for 3/4" elbow CV3162-013 1.3 DLFC for 3/4" elbow CV3162-017 1.7 DLFC for 3/4" elbow CV3162-022 2.
REPLACEMENT PARTS: WATER METER & METER PLUG Item No. Part No. Description Qty. 1 CV3151 Nut, 1" QC 1 2 CV3003 Meter assembly, includes items 3 & 4 1 3 CV3118-01 Turbine assembly 1 4 CV3105 O-ring 215 1 5 CV3003-01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 SERVICE WRENCH - CV3193-01 Although no tools are necessary to assemble or disassemble the valve, the Service Wrench, (shown in various positions on the valve) is available to aid in assembly or disassembly.
REPLACEMENT PARTS: BRINE TANK ASSEMBLY Item No. Part No. CG2195-14 CG2189 CG21517RB1CDL 2 CG21840CB1C00 CH1030-27 3 CH1030-34.5 4 CH1018 5 CH4500-48 6 CH4640-32 7 CH4600-50 8 CH7016 9 CH4626 ASSEMBLIES CH4700-27WR-1 10 CH4700-34.5WR-1 1 Description Qty. 15" x 17" DuPure brine tank cover Round brine tank cover, black 15" x 17" platinum brine tank 18" x 40" round brine tank, black 4" x 27" brine well (18 x 33 BT) 4" x 34.
REPLACEMENT PARTS: CABINET BRINE TANK ASSEMBLY Item No. Part No. 1 CG 2197-01 2 CG2724HP-01 3 Description Qty. Salt and tank cover (must be ordered together 1 Windsor cabinet, white with black lids 1 CH1090-01 Optional salt grid for 8" diameter tank and 4" brine well 1 CH1090-02 Optional salt grid for 9" diameter tank and 4" brine well 1 CH1090-03 Optional salt grid for 10" diameter tank and 4" brine well 1 1 See opposite page for safety float system parts.
INSTALLATION FITTING ASSEMBLIES: 1" PVC MALE NPT ELBOW Item No. 1 2 3 4 Part No. Description CV3007 CV3151 CV3150 CV3105 CV3149 1" PVC male NPT elbow assembly Nut, 1" quick connect Split ring O-ring 215 Fitting 3/4" & 1" PVC SOLVENT ELBOW Item No. Qty. 2 2 2 2 2 1 2 3 4 1" BRASS SWEAT Item No. 1 2 3 4 Part No. CV3007- 02 CV3151 CV3150 CV3105 CV3188 Description 1" brass sweat assembly Nut, 1" quick connect Split ring O-ring 215 Fitting 1 2 3 4 Part No.
1-1/4" & 1-1/2" BRASS SWEAT Item No. 1 2 3 4 1-1/4" & 1-1/2" PVC SOLVENT Part No. Description Qty. CV3007- 09 CV3151 CV3150 CV3105 CV3375 1-1/4 & 1-1/2" brass sweat assembly Nut, 1" quick connect Split ring O-ring 215 Fitting 2 2 2 2 2 Item No. 1 2 3 4 Part No. Description Qty. CV3007- 07 CV3151 CV3150 CV3105 CV3352 1-1/4" & 1-1/2" PVC solvent assembly Nut, 1" quick connect Split ring O-ring 215 Fitting 2 2 2 2 2 SPECIFICATIONS: CAPACITY SPECIFICATIONS IMP-844 MODEL Capacity: (Grains/Lbs.
QUICK REFERENCE GUIDE: GENERAL OPERATION MANUAL REGENERATION When the system is operating, one of three displays will be shown: time of day, gallons of treated water available, or gallons per minute. Pressing NEXT will toggle between the three choices. NOTE: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regeneration.