PROGRAMMING MODE continued
Level III Cycle Programming - C Values
Several Level III program parameters can be adjusted to
ne-tune valve operation for non-standard applications.
Typically these parameters will not need to be adjusted as
the default settings accommodate most applications. Contact
your Water Treatment Professional before attempting any
programming. The parameters are accessible by pressing and
holding the UP and SET buttons until the display shows a “C”
value.
NOTE: The control must be in the treated water position to
change settings.
C# Description Range
Minimum
Increments
Default Setting Notes
C1*
Brine Draw 0-200
1 Min
See Notes
Automatically calculated from resin volume
and salt dosage settings and draw rate.
C2
Slow Rinse 0-200 See Notes
Initial time automatically calculated to provide
two bed volumes of rinse.
C3
Standard Backwash 0-20 7
Flow rate dictated by size of drain line ow
controller.
C4 Standard Fast Rinse 0-200 3 Rinses residual regenerant from tank.
C5*
Rell 0-200 See Notes
Automatically calculated from resin volume
and salt dosage settings and rell rate.
C13
Cleaning Backwash 0-200 14
Control uses C13 in place of C3 when the
number of standard regenerations is more than
or equal to the cleaning cycle interval P19.
C14
Cleaning Fast Rinse 0-200 6
Control uses C14 in place of C4 when the
number of standard regenerations is more than
or equal to the cleaning cycle interval P19.
*Cannot be changed in Level III Cycle Programming.
9100 TS Upow JA11 • 9