Owner manual
Level II Programming - P Values
Level II Programming parameters can be adjusted to ne-tune
the conditioner's operation. The parameters are accessible
by pressing and holding the UP and DOWN buttons until the
control displays a "P" value.
NOTE: The control must be in the home position to
change settings. See Table for Level II parameters.
Typically the Level II parameters will not need to
be adjusted as the default settings accommodate
most applications. Contact your water treatment
professional before attempting any programming.
Description Range
Minimum
Increments
Default Units Notes
P9 Units of Measure 0-1 1 (2) 0 = US 1 = Metric
P10 Clock Mode 0-3 1 (2)
0 = 12 hour clock: ow rate displayed
1 = 24 hour clock: ow rate displayed
2 = 12 hour clock; Time of Day displayed
3 = 24 hour clock; Time of Day displayed
P11 Service Interval 0-99 1 0 Months
0 = Dissabled. Number of days per month is
xed at 30.
P12*
Resin Tank Sensor
Placement
60-01 1 20 % of Capacity
Expressed as a percentage of resin bed capacity
remaining after lowest set of pins.
P13
Disable Resin Tank
Sensors
0-1 1 0
0 = Resin Tank Sensors Enabled
1 = Resin Tank Sensors Disabled
P14 Rell Rate 1-700 1 (1) gpm x 100 Used with salt amount to calculate rell time.
P15 Draw Rate 1-700 1 (1) gpm x 100 Used with salt amount to calculate draw time.
P16 Flow sensor select 1-4 1 4
1 = 1" Autotrol turbine
2 = 2" Autotrol turbine
3 = User dened K-factor
4 = Fleck 3/4" Paddle
5 = Fleck 3/4" Turbine
6 = Fleck 1" Paddle
7 = Fleck 1"/1-1/2" Turbine
8 = Fleck 1-1/2" Paddle
9 = Meter Factor
P17
K-factor or Pulse
equivalent
0.01-99.99 0.01 0.01
K-factor P16 = 3;
Pulse Equivalent P16 = 9
P18 Tank in Service 1-2 1 1 Select the Tank in Service.
P19 Cleaning Cycle Interval 0-100 1 6
Number of standard regeneration cycles
between cleaning regeneration cycles.
*The control will automatically adjust the Hardness Setting P8 when the sensors in the resin tank detect a hardness front passing. This automatic
adjustment to the hardness setting may result in the system passing hard water near the end of the service cycle if the resin tank sensor
placement setting P12 is wrong. The sensor placement setting P12 must be reduced to eliminate the problem. Reducing the Capacity Setting
P7 or increasing the Hardness setting P8 will only produce a temporary solution.
NOTE: (1) Default selected with initial setting value.
(2) Facotry Default is "0" for North America units and "1" for World units.
PROGRAMMING MODE continued
8 • JA11 9100 TS Upow