User Manual

14 15
More than 140 different parameter-methods to choose from!
All PrimeLab 2.0 parameter-curves are calibrated to quality reagents, developed and produced
them on PrimeLab!
Over almost 2 decades, Water-i.d. developed reagents and Photometer-curves for more than
Just like the PrimeLab 1.0, the PrimeLab 2.0 offers water testing solutions for many different
industries, testing almost every parameter from A for Alkalinity to Z for Zinc.
in Germany and UK. Users can also define their own curves, using all 18 wavelengths, and store
140 different parameter-methods.
*if parameter and range repeats, different reagents are used (e.g. liquid reagents instead of tablets)
*if parameter and range repeats, different reagents are used (e.g. liquid reagents instead of tablets)
© Water-i.d. GmbH / Germany
Reagents
DEVELOPED
and PRODUCED
in GERMANY
Water Plants
Cooling Towers
Potable Water
Waste Water
Boiler Water
Food processing
Laboratories
Marine Industry
PLPar155
PLPar145
PLPar143
PLPar1
PLPar5
PLPar121
PLPar6
PLPar4
PLPar2
PLPar125
PLPar146
PLPar141
PLPar142
PLPar126
PLPar63
PLPar128
PLPar10
PLPar124
PLPar12
PLPar129
PLPar167
PLPar122
PLPar8
PLPar71
PLPar95
PLPar11
PLPar14
PLPar7
PLPar144
Acsamine DWBR1
Boron
Alkalinity-P
Ammonia (LR)
Chloramines
Alkalinity-M
Alkalinity-M (HR)
Aluminium
Ammonia (HR)
Acsamine 28F
Acsamine CC
Active Oxygen
Acsamine CCA
Acsamine DW
Acsamine DWC
Acsamine SW
Acsamine SWC
Bromine
Bromine
Bromine
Carbohydrazide
Chloride
Chloride
Chloride in Methanol
Chlorine (free-combined-total)
Chlorine (free-combined-total)
Chlorine (free)
Chlorine (HR)
Chlorine (MR)
0 - 0.3 mg/l
0 - 100 mg/l
0 - 20 mg/l
0 - 18 mg/l
1 - 50 mg/l
0 - 100 mg/l
0.00 - 8.00 mg/l
0.00 - 8.00 mg/l
0 - 100 mg/l
0 - 4.5 mg/l
0 - 1.3 mg/l
5 - 200 mg/l
0.00 - 8.00 mg/l
0.00 - 10.00 mg/l
0 - 100 mg/l
0 - 500 mg/l
0 - 1 mg/l
0 - 100 mg/l
0 - 2 mg/l
0 - 2 mg/l
0 - 100 mg/l
0 - 100 mg/l
0 - 100 mg/l
0 - 18 mg/l
0 - 100 mg/l
0.5 - 25 mg/l
5 - 300 mg/l
5 - 200 mg/l
0 - 40 mg/l
1
0.01
0.01
1
1
0.1
0.1
0.01
1
0.1
0.1
1
1
0.1
1
0.01
1
1
0.01
1
0.01
1
1
0.01
0.01
0.01
0.01
0.01
0.01
PLPar163
PLPar82
PLPar65
PLPar70
PLPar80
PLPar78
PLPar148
PLPar162
PLPar109
PLPar67
PLPar18
PLPar20
PLPar56
PLPar21
PLPar160
PLPar57
PLPar19
PLPar23
PLPar66
PLPar25
PLPar28
PLPar72
PLPar27
PLPar113
PLPar9
PLPar24
PLPar107
PLPar26
PLPar158
PLPar17
PLPar166
PLPar106
PLPar130
PLPar94
PLPar103
PLPar79
PLPar64
PLPar15
PLPar108
PLPar16
Chlorine (HR)
Chlorine Dioxide
Total Oxidant
COD (MR)
COD (HR)
Chlorine Dioxide
Chlorite
Colour
Copper
Cyanide
COD (LR)
Copper
Cyanuric Acid
Chlorine Dioxide
Chromium
DBNPA
Chromium
Erythorbic Acid
Hardness-Calcium
Hydroquinone
Hydrogen Peroxide (LR)
Hydrogen Peroxide (HR)
Hydrazine
Hardness-Total HR
Hardness-Total LR
Iron (LR)
Dissolved Oxygen
Hardness-Calcium
Hardness total (HR)
Hydrogen Peroxide (HR)
DEWAN-50
Hardness-Calcium (HR)
DBNPA
Fluorescein
Hydrogen Peroxide (LR)
Fluoride
Iodine
Hydrocarbons in Methanol (tank wash)
Iodine
DEHA
0 - 15 mg/l
0 - 8 g/l
0 - 200 mg/l
0 - 8 mg/l
0 - 1 mg/l
15 - 500 mg/l
2 - 160 mg/l
0 - 13 mg/l
0 - 13 mg/l
0 - 15000 mg/l
20 - 1000 µl/l
0 - 5 mg/l
0 - 2.2 mg/l
0 - 10 mg/l
0 - 1500 mg/l
0 - 150 mg/l
0 - 15 mg/l
0 - 5 mg/l
0 - 5 mg/l
0.01 - 0.50 mg/l
0 - 200 mg/l
0 - 500 mg/l
0 - 2.5 mg/l
0 - 500 mg/l
5 - 600 µl/l
50 - 1000 mg/l
0 - 200 mg/l
0 - 3.5 mg/l
0 - 3.8 mg/l
2 - 50 mg/l
yes/no
0 - 2 mg/l
0 - 300 mg/l
20 - 500 mg/l
0 - 500 µl/l
0 - 28 mg/l
0 - 28 mg/l
0 - 1 mg/l
0 - 500 mg/l
0 - 3.8 mg/l
1
0.01
0.01
0.01
0.01
1
1
0,01
1
1
1
0.01
0.01
0.01
1
1
1
0.01
0,01
1
0,01
0.01
1
0.01
1
1
10
0.1
0.01
1
0.01
0.01
1
1
0.01
1
0,
01
1
0,01
0,01
Code Parameter Range Resolution
Code Parameter Range Resolution