To reduce the risk associated with property damage due to water leakage:
• Read and follow UseInstructionsbeforeinstallationanduseofthissystem.
• Installationanduse MUST comply with all state and local plumbing codes.
•
Protect from freezing,removeltercartridgewhentemperaturesareexpectedtodropbelow40°F(4.4°C)
.
•
Donotinstallsystemsinareaswhereambienttemperaturesmaygoabove110°F(43.3°C)
.
• Donotinstallonhotwatersupplylines.Themaximumoperatingwatertemperatureofthisltersystem
is100°F(37.8°C).
• Donotinstallifwaterpressureexceeds100psi(690kPa).Ifyourwaterpressureexceeds80psi(552
kPa),youmustinstallapressurelimitingvalve.Contactaplumbingprofessionalifyouareuncertainhow
to check your water pressure.
•
Donotinstallwherewaterhammerconditionsmayoccur.Ifwaterhammerconditionsexistyoumustinstalla
water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
•
Wherebackowpreventiondeviceisinstalledonawatersystem,adeviceforcontrollingpressuredueto
thermalexpansionmustbeinstalled.
• Donotuseatorchorotherhightemperaturesourcesnearltersystem,cartridges,plasticttingsor
plastic plumbing.
• Onplasticttings,neverusepipesealantorpipedope.UsePTFEthreadtapeonly, pipe dope properties
may deteriorate plastic.
• Takecarewhenusingpliersorpipewrenchestotightenplasticttings,asdamagemayoccurifovertight-
ening occurs.
• Donotinstall in direct sunlight or outdoors.
• Allhydro-pneumatictanksmusthaveanappropriatepressurereliefvalveinstalled.
• Donot install near water pipes which will be in path of a drilling tool when selecting the position to mount
the bracket.
•
Mountlterinsuchapositionastopreventitfrombeingstruckbyotheritemsusedintheareaofinstallation.
• Ensurethatthelocationandfastenerswillsupporttheweightofthesystemwheninstalled.
• Ensurealltubingandttingsaresecureandfreeofleaks.
•
Donotinstallunitifcolletismissing.ContactWaterFactorySystemsifcolletsaremissingfromanyttings.
• SHUTOFFFUELORELECTRICPOWERSUPPLYTOWATERHEATERafterwaterisshutoff.
• ThedisposableltercartridgeMUST bereplacedevery12months,orsoonerifanoticeablereductionin
owrateoccurs.
• TheROMembranecartridgeMUST bereplacedatleastevery36months.
To reduce the risk of eye injury while drilling counter-tops for faucet installation:
Safety glasses MUST be worn during the sink hole drilling operations.
To reduce the risk of eye injury while drilling counter-tops for faucet installation:
Safety glasses MUST be worn during the sink hole drilling operations.
To reduce the risk of injury associated with household bleach:
Read and follow manufacturers directions and cautions
Keep out of the reach of children
DONOTintermixwithotherchemicals
• Failure to install, operate, or maintain your drinking water appliance in accordance with
these use instructions or any other installation or use instructions accompanying this
product may result in product failure and property damage, including water leakage and