User manual

52
WPL 612 User Manual
Gap Mode 1/4
>
Automatic
Manual
Pre-Printed
A. Gap Mode
Calibration 1/4
>
Gap Mode
Bline Mode
Cont. Mode
Press the and buttons to scroll the cursor to the media type and press
the button to enter the sensor calibration mode.
Note: If printing from enclosed software/driver, the software/driver will send
out the GAP or BLINE command, which will overwrite the sensor type
setting set from the front panel.
A-1 Automatic
When enter the [Automatic] option, you will see following message, and
printer will feed 2 to 3 gap labels to calibrate the sensor sensitivity
automatically. When calibration is completed, the LCD screen will return to
the previous menu.
Gap Mode
Automatic
A-2 Manual
In case “Automatic” sensor calibration cannot apply to the media, please
use “Manual” function to calibrate the gap sensor manually.
Gap Mode 2/4
Automatic
>
Manual
Pre-Printed
When enter [Manual] option, you will see following message. Please
complete there steps
Paper Len.
00812 dot
1. Press the button to move
the cursor from left digit to right digit,
and press the button to set
mm/ inch”. Press the
button to
set
the
paper length into the
printer.