User`s manual
23
Gap/Black Mark Sensor
Calibratio, Label Len
g
th
Measurement, Self
Test and enter Dump
Mode
1.Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED becomes amber and blinking. (Any amber
will do during the 5 blinks).
The LED color will be changed as following order.
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green
It calibrates the sensor and measures the label length and prints
internal settings then enter the dump mode.
Note:
Please select gap or black mark sensor by GAP or BLINE command
prior to calibrate the sensor.
For more information about GAP and BLINE command, please refer to
WPL programming manual.
Printer Initialization
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green after 5 amber blinks. (Any
green will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green
Always do gap/black mark sensor calibration after printer
initialization.
Black Mark Sensor
Calibration
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5 green blinks.
(Any green/amber will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks)
green/amber (5 blinks) red/amber (5 blinks) solid green