User`s manual
16
4.4 Black Mark Sensor Calibration
Set black mark sensor as media sensor and calibrate the black mark sensor.
Follow the steps below.
1. Turn off the power switch.
2. Press and hold the Feed button while turning the power back on.
3. Release the button when LED turns green/amber after 5 green blinks. (Any green/amber
will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5
blinks) red/amber (5 blinks) solid green
4.5 Gap Sensor Calibration
Set gap sensor as media sensor and calibrate the gap sensor.
Follow the steps below.
1. Turn off the power switch.
2. Press and hold the Feed button while turning the power back on.
3. Release the button when LED turns red/amber after 5 green/amber blinks. (Any red/amber
will do during the 5 blinks).
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5
blinks) red/amber (5 blinks) solid green
4.6 Skip AUTO.BAS
WPL programming language allows you to download an auto execution file to flash memory.
The printer will run the AUTO.BAS program immediately after you turn it on. The AUTO.BAS
program can be interrupted without running the program by the power-on utility.
Follow the steps below:
1. Turn off printer power.
2. Press and hold the Feed button while turning the power back on.
3. Release the FEED button when LED becomes solid green.
The LED color will be changed as following:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5
blinks) red/amber (5 blinks) solid green
4. Printer will be interrupted to run the AUTO.BAS program.