USER MANUAL Wasp WLS 9500 w w w. w a s p b a rc o d e .
WLS 9500 Product Reference Guide April 2006
© 2006 by Wasp Technologies. All rights reserved. No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Wasp Technologies. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice. The software is provided strictly on an “as is” basis.
Contents About This Guide Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Notational Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Service Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii Chapter 1. Getting Started Introduction . .
vi WLS 9500 Product Reference Guide Chapter 3. Maintenance, Troubleshooting & Technical Specifications Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents USB Interface Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 Connecting a USB Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3 USB Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 USB Host Parameters . . . . . . . . . . . . . . . . . . .
viii WLS 9500 Product Reference Guide Code 32 Prefix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-23 Set Lengths for Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-24 Code 39 Check Digit Verification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-25 Transmit Code 39 Check Digit . . . . . . . . . . . . . . . . . . . . .
Contents Bi-directional Redundancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-53 Symbology - Intercharacter Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-54 Chapter 8. Miscellaneous Scanner Options Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Scanning Sequence Examples. . . . . . . . . . .
x WLS 9500 Product Reference Guide
About This Guide Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv Notational Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv Related Publications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi Wasp Support Information . . . . . . . . . . . . . . . .
xii WLS 9500 Product Reference Guide
xiii Introduction The WLS 9500 Product Reference Guide provides general instructions for setting up, operating, maintaining, and troubleshooting the WLS 9500 scanner. The scanner includes the following variations of the scanner: Notational Conventions The following conventions are used in this document: • • • Bullets (•) indicate: • action items • lists of alternatives • lists of required steps that are not necessarily sequential. Sequential lists (e.g.
xiv WLS 9500 Product Reference Guide
1 Getting Started Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Setting Up the Scanner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Installing the Interface Cable . . . . . . . . . .
1-2 WLS 9500 Product Reference Guide
Getting Started 1-3 Introduction The scanner combines excellent scanning performance and advanced ergonomics to provide the best value in a lightweight laser scanner. Whether used as a hand-held scanner or in hands-free mode in a stand, the scanner ensures comfort and ease of use for extended periods of time. In addition to single-line laser scanning, the scanner supports multi-line rastering.
1-4 WLS 9500 Product Reference Guide Setting Up the Scanner Installing the Interface Cable To connect the interface cable: 1. Insert the interface cable’s modular connector clip into the cable interface port on the bottom of the scanner handle. (See Figure 1-2.). 2. Gently tug the cable to ensure the connector is properly secured. 3. Connect the other end of the interface cable to the host. (See the specific host chapter for information on host connections.
2 Scanning Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Beeper Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 LED Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 Scanning in Hand-Held Mode . . . . . . . . . . . . . . .
2-2 WLS 9500 Product Reference Guide
Scanning 2-3 Introduction This chapter provides beeper and LED definitions, techniques involved in scanning bar codes, general instructions and tips about scanning, and decode zone diagrams. LED Scan Window Beeper Trigger Figure 2-1.
2-4 WLS 9500 Product Reference Guide Beeper Definitions The scanner issues different beep sequences and patterns to indicate status. Table 2-1 defines beep sequences that occur during both normal scanning and while programming the scanner. Table 2-1. Beeper Definitions Beeper Sequence Indication Standard Use Low/medium/high beeps Power up. Short high beeps A bar code symbol was decoded (if decode beeper is enabled). 4 long low beeps A transmission error was detected in a scanned symbol.
Scanning 2-5 Table 2-2. Standard LED Definitions LED Indication Red A data transmission error or scanner malfunction occurred. Scanning in Hand-Held Mode Install and program the scanner (see Setting Up the Scanner on page 1-4). For assistance, contact the local supplier or Wasp Technologies. To scan in hand-held mode: 1. Ensure all connections are secure. (See the host chapter for the scanner.) 2. Aim the scanner at the bar code. 3. Press the trigger.
2-6 WLS 9500 Product Reference Guide When scanning using a multi-line scan mode, at least one scan line must cross every bar and space of the symbol. 012345 012345 Figure 2-4. Acceptable and Incorrect Multi-Line Aiming Regardless of the scan mode, the scan line is smaller when the scanner is closer to the symbol and larger when it is farther from the symbol.
Scanning 2-7 The scanner can be tilted up to 65° forward or back and achieve a successful decode (Figure 2-5). Simple practice quickly shows what tolerances to work within. 65 65 o o Figure 2-5.
2-8 WLS 9500 Product Reference Guide Scanning in Hands-Free Mode The optional Intellistand adds greater flexibility to scanning operation. When the scanner is seated in the stand’s “cup,” the scanner’s built-in sensor places the scanner in hands-free mode. When the scanner is removed from the stand, it automatically switches modes to operate in its normal hand-held triggered mode. Assemble the Stand Figure 2-6.
Scanning 2-9 Scanning with the WLS 9500 Hands Free Stand When the scanner is placed in the Intellistand, the scan pattern selected in hand-held triggered mode continues (see Scan Pattern on page 4-7). To operate the scanner in the WLS 9500 Hands Free Stand: 1. Ensure the scanner is properly connected to the host (see the appropriate host chapter for information on host connections). 2. Insert the scanner in Intellistand by placing the front of the scanner into the stand’s “cup.
2-10 WLS 9500 Product Reference Guide Decode Zone in. cm 15 38.1 10 25.4 5 12.7 0 0 5 12.7 10 25.4 15 38.1 Note: Typical performance at 73° F (23° C) on high quality symbols in normal room light. LS 4208 1.5 5 mil 5.5 10 mil * 14.5 13 mil 19 20 mil in. 0 cm 0 5 12.7 29 10 25.4 15 38.1 20 50.8 25 63.5 30 76.2 Depth of Field *Minimum distance determined by symbol length and scan angle Figure 2-8. WLS 9500 Decode Zone 35 88.9 40 101.
3 Maintenance, Troubleshooting & Technical Specifications Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2 WLS 9500 Product Reference Guide
Maintenance, Troubleshooting & Technical Specifications 3-3 Introduction This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts). Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy.
3-4 WLS 9500 Product Reference Guide Table 3-1. Troubleshooting (Continued) Problem Possible Causes Possible Solutions The scan line is not crossing every bar and space of the symbol. Move the symbol until the scan line is within the acceptable aiming pattern. See Figure 2-3 on page 2-5. Scanner decodes bar code, but does not transmit Scanner is not programmed for the correct the data to the host. host type. Scan the appropriate host type programming bar code.
Maintenance, Troubleshooting & Technical Specifications 3-5 If after performing these checks the symbol still does not scan, contact the distributor or call Wasp Technologies. See page xvi for the telephone number.
3-6 WLS 9500 Product Reference Guide Technical Specifications Table 3-2. Technical Specifications Item Description Physical Characteristics Dimensions: 6.7 in. H x 3.7 in. L x 2.7 in. W (17 cm H x 9.3 cm L x 6.8 cm W) Weight (without cable) Approximately 6.4 oz.
Maintenance, Troubleshooting & Technical Specifications 3-7 Table 3-2. Technical Specifications (Continued) Item ESD Description 15 kV air discharge 8 kV indirect discharge Regulatory Electrical Safety UL1950, CSA C22.2 No.
3-8 WLS 9500 Product Reference Guide
4 User Preferences Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Scanning Sequence Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Errors While Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 User Preferences Parameter Defaults. . . . . . . . . . . . . .
4-2 WLS 9500 Product Reference Guide
User Preferences 4-3 Introduction If desired, program the scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides the programming bar codes necessary for selecting these features. The scanner ships with the settings shown in the User Preferences Default Table on page 4-4 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults).
4-4 WLS 9500 Product Reference Guide User Preferences Parameter Defaults Table 4-1 lists the defaults for user preferences parameters. To change any option, scan the appropriate bar code(s) provided in the User Preferences section beginning on page 4-5. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 4-1.
User Preferences 4-5 User Preferences Default Parameters The scanner can be reset to two types of defaults: factory defaults or custom defaults. Scan the appropriate bar code below to reset the scanner to its default settings and/or set the scanner’s current settings as the custom default.
4-6 WLS 9500 Product Reference Guide Beeper Tone To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code. Low Frequency *Medium Frequency (Optimum Settings) High Frequency Beeper Volume To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
User Preferences 4-7 Power Mode This parameter determines whether or not power remains on after a decode attempt. When in reduced power mode, the scanner enters into a low power consumption mode to preserve battery life after each decode attempt. When in continuous power mode, power remains on after each decode attempt. *Continuous On Reduced Power Mode Scan Pattern This parameter determines the pattern (mode) of scanning. Scan the appropriate bar code below to set the scanning mode.
4-8 WLS 9500 Product Reference Guide Scan Line Width Scan a bar code below to set the scan line width. *Full Width Medium Width Small Width Laser On Time This parameter sets the maximum time that decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default Laser On Time is 3.0 seconds. To set a Laser On Time, scan the bar code below.
User Preferences 4-9 Beep After Good Decode Scan a bar code below to select whether or not the scanner beeps after a good decode. If Do Not Beep After Good Decode is selected, the beeper still operates during parameter menu scanning and indicates error conditions.
4-10 WLS 9500 Product Reference Guide
5 Keyboard Wedge Interface Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Connecting a Keyboard Wedge Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3 Keyboard Wedge Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4 Keyboard Wedge Host Parameters . . . . . . . . . . . . . . . . . . . . .
5-2 WLS 9500 Product Reference Guide
Keyboard Wedge Interface 5-3 Introduction This chapter describes how to set up a Keyboard Wedge interface with the scanner. With this interface, the scanner is connected between the keyboard and host computer, and translates bar code data into keystrokes. The host computer accepts the keystrokes as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input. Keyboard keystrokes are simply passed through.
5-4 WLS 9500 Product Reference Guide 9. To modify any other parameter options, scan the appropriate bar codes in this chapter. Keyboard Wedge Parameter Defaults Table 5-1 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section beginning on page page 5-5. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 5-1.
Keyboard Wedge Interface 5-5 Keyboard Wedge Host Parameters Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below. IBM PC/AT & IBM PC Compatibles1 IBM AT Notebook NCR 7052 1User selection is required to configure this interface and this is the most common selection.
5-6 WLS 9500 Product Reference Guide Keyboard Wedge Country Types (Country Codes) Scan the bar code corresponding to the keyboard type. If the keyboard type is not listed, see Alternate Numeric Keypad Emulation on page 5-9.
Keyboard Wedge Interface 5-7 Keyboard Wedge Country Types (continued) Swedish Windows UK English Windows Japanese Windows Portuguese-Brazilian Windows Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the scanner.
5-8 WLS 9500 Product Reference Guide Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data. *No Delay Medium Delay (20 msec) Long Delay (40 msec) Intra-Keystroke Delay When enabled, an additional delay is inserted between each emulated key depression and release. This sets the Keystroke Delay parameter to a minimum of 5 msec as well.
Keyboard Wedge Interface 5-9 Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types (Country Codes) on page 5-6 in a Microsoft® operating system environment. Enable Alternate Numeric Keypad *Disable Alternate Numeric Keypad Caps Lock On When enabled, the scanner emulates keystrokes as if the Caps Lock key is always pressed.
5-10 WLS 9500 Product Reference Guide Convert Wedge Data When enabled, the scanner will convert all bar code data to the selected case. Convert to Upper Case Convert to Lower Case *No Convert Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table 5-2 on page 5-13). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not this parameter is enabled.
Keyboard Wedge Interface 5-11 FN1 Substitution When enabled, the scanner replaces FN1 characters in an EAN128 bar code with a keystroke chosen by the user (see FN1 Substitution Values on page 8-8). Enable FN1 Substitution *Disable FN1 Substitution Send Make and Break When enabled, the scan codes for releasing a key are not sent.
5-12 WLS 9500 Product Reference Guide Keyboard Maps The following keyboard maps are provided for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 8-5. 5001 5002 5003 5004 7008 7009 7014 7012 7003 7013 5005 5006 5007 5008 5009 5010 7004 7011 Figure 5-2.
Keyboard Wedge Interface 5-13 ASCII Character Set for Keyboard Wedge Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >. Table 5-2.
5-14 WLS 9500 Product Reference Guide Table 5-2. Keyboard Wedge ASCII Character Set (Continued) 1The ASCII Value Full ASCII Code 39 Encode Character Keystroke 1027 %A CTRL [ /ESC1 1028 %B CTRL \ 1029 %C CTRL ] 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
Keyboard Wedge Interface 5-15 Table 5-2.
5-16 WLS 9500 Product Reference Guide Table 5-2.
Keyboard Wedge Interface 5-17 Table 5-2. Keyboard Wedge ASCII Character Set (Continued) ASCII Value Full ASCII Code 39 Encode Character Keystroke 1126 %S ~ 1 The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent. Table 5-3.
5-18 WLS 9500 Product Reference Guide Table 5-4.
Keyboard Wedge Interface 5-19 Table 5-4. Keyboard Wedge GIU Key Character Set (Continued) GUI Keys Keystrokes 3090 GUI Z Table 5-5. Keyboard Wedge F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019 F19 5020 F20 5021 F21 5022 F22 5023 F23 5024 F24 Table 5-6.
5-20 WLS 9500 Product Reference Guide Table 5-6. Keyboard Wedge Numeric Keypad Character Set (Continued) Numeric Keypad Keystroke 6044 undefined 6045 - 6046 . 6047 / 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Table 5-7.
Keyboard Wedge Interface 5-21 Table 5-7.
5-22 WLS 9500 Product Reference Guide
6 USB Interface Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 Connecting a USB Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3 USB Parameter Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4 USB Host Parameters . . . . . . . . . . . . . . . . . . . . . . .
6-2 WLS 9500 Product Reference Guide
USB Interface 6-3 Introduction This chapter covers the connection and setup of the scanner to a USB host. The scanner attaches directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. Throughout the programming bar code menus, default values are indicated with asterisks (*). *North American Standard USB Key- * Indicates Default Feature/Option Connecting a USB Interface USB Series A Connector Interface cable Figure 6-1.
6-4 WLS 9500 Product Reference Guide To set up the scanner: Interface cables vary depending on configuration. The connectors illustrated in Figure 6-1are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same. 1. Attach the modular connector of the USB interface cable to the cable interface port on the scanner (see Installing the Interface Cable on page 1-4). 2. Plug the series A connector in the USB host or hub. 3.
USB Interface 6-5 USB Host Parameters USB Device Type Select the desired USB device type. When changing USB Device Types, the scanner automatically restarts. The scanner issues the standard startup beep sequences.
6-6 WLS 9500 Product Reference Guide USB Country Keyboard Types (Country Codes) Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. When changing USB country keyboard types the scanner automatically resets. The scanner issues the standard startup beep sequences.
USB Interface 6-7 USB Country Keyboard Types (Country Codes continued) Italian Windows Swedish Windows UK English Windows Japanese Windows (ASCII) Portuguese-Brazilian Windows
6-8 WLS 9500 Product Reference Guide USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data. *No Delay Medium Delay (20 msec) Long Delay (40 msec) USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device. When enabled, the case of the data is preserved regardless of the state of the caps lock key.
USB Interface 6-9 USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character, then the scanner issues an error beep.
6-10 WLS 9500 Product Reference Guide USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device. When enabled, this allows replacement of any FN 1 characters in an EAN 128 bar code with a Key Category and value chosen by the user (see FN1 Substitution Values on page 13-8 to set the Key Category and Key Value).
USB Interface 6-11 Simulated Caps Lock When enabled, the scanner will invert upper and lower case characters on the scanner bar code as if the Caps Lock state is enabled on the keyboard. This inversion is done regardless of the current state of the keyboard’s Caps Lock state. *Disable Simulated Caps Lock Enable Simulated Caps Lock Convert Case When enabled, the scanner will convert all bar code data to the selected case.
6-12 WLS 9500 Product Reference Guide ASCII Character Set for USB Table 6-2.
USB Interface 6-13 Table 6-2. ASCII Character Set for USB (Continued) 1The ASCII Value Full ASCII Code 39 Encode Character Keystroke 1030 %D CTRL 6 1031 %E CTRL - 1032 Space Space 1033 /A ! 1034 /B “ 1035 /C # 1036 /D $ 1037 /E % 1038 /F & 1039 /G ‘ 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
6-14 WLS 9500 Product Reference Guide Table 6-2.
USB Interface 6-15 Table 6-2.
6-16 WLS 9500 Product Reference Guide Table 6-3.
USB Interface 6-17 Table 6-4.
6-18 WLS 9500 Product Reference Guide Table 6-4. USB GUI Key Character Set (Continued) GUI Key Keystroke 3088 GUI X 3089 GUI Y 3090 GUI Z Note: GUI Shift Keys - The Apple™ iMac keyboard has an apple key on either side of the space bar. Windowsbased systems have a GUI key to the left of the left ALT key, and to the right of the right ALT key. Table 6-5.
USB Interface 6-19 Table 6-6. USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 * 6043 + 6044 undefined 6045 - 6046 .
6-20 WLS 9500 Product Reference Guide Table 6-7.
7 Symbologies Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-5 Scanning Sequence Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-5 Errors While Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-5 Symbology Parameter Defaults . . . . . . . . . . . . . . . . . . . . .
7-2 WLS 9500 Product Reference Guide Enable/Disable Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enable/Disable Trioptic Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convert Code 39 to Code 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbologies 7-3 Redundancy Level 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-48 Redundancy Level 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-48 Redundancy Level 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-4 WLS 9500 Product Reference Guide
Symbologies 7-5 Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 1, Getting Started. The scanner is shipped with the settings shown in the Symbology Parameter Defaults on page 7-6 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary.
7-6 WLS 9500 Product Reference Guide Symbology Parameter Defaults Table 7-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on 7-9. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies and miscellaneous default parameters. Table 7-1.
Symbologies 7-7 Table 7-1.
7-8 WLS 9500 Product Reference Guide Table 7-1.
Symbologies 7-9 UPC/EAN Enable/Disable UPC-A/UPC-E To enable or disable UPC-A or UPC-E, scan the appropriate bar code below.
7-10 WLS 9500 Product Reference Guide Enable/Disable UPC-E1 UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below. UPC-E1 is not a UCC (Uniform Code Council) approved symbology. Enable UPC-E1 *Disable UPC-E1 Enable/Disable EAN-13/EAN-8 To enable or disable EAN-13 or EAN-8, scan the appropriate bar code below.
Symbologies 7-11 Enable/Disable Bookland EAN To enable or disable Bookland EAN, scan the appropriate bar code below. Enable Bookland EAN *Disable Bookland EAN Decode UPC/EAN/JAN Supplementals Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available. • • • • • • If Decode UPC/EAN/JAN Only With Supplementals is selected, UPC/EAN symbols without supplementals are not decoded.
7-12 WLS 9500 Product Reference Guide Decode UPC/EAN/JAN Supplementals (continued) Decode UPC/EAN/JAN Only With Supplementals *Ignore Supplementals Autodiscriminate UPC/EAN/JAN Supplementals Enable 378/379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart Supplemental Mode
Symbologies 7-13 UPC/EAN/JAN Supplemental Redundancy With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to thirty times. Five or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the autodiscriminate option is selected. The default is set at 7. Scan the bar code below to set a decode redundancy value.
7-14 WLS 9500 Product Reference Guide Transmit UPC-E Check Digit The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E check digit. It is always verified to guarantee the integrity of the data.
Symbologies 7-15 Transmit UPC-E1 Check Digit The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate bar code below to transmit the bar code data with or without the UPC-E1 check digit. It is always verified to guarantee the integrity of the data. *Transmit UPC-E1 Check Digit Do Not Transmit UPC-E1 Check Digit UPC-A Preamble Preamble characters are part of the UPC symbol consisting of Country Code and System Character.
7-16 WLS 9500 Product Reference Guide UPC-E Preamble Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Three options are given for transmitting UPC-E preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and no preamble transmitted. Scan a bar code below to match the host system.
Symbologies 7-17 UPC-E1 Preamble Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Three options are given for transmitting UPC-E1 preamble to the host device: transmit System Character only, transmit System Character and Country Code (“0” for USA), and no preamble transmitted. Scan a bar code below to match the host system.
7-18 WLS 9500 Product Reference Guide Convert UPC-E1 to UPC-A Enable this to convert UPC-E1 decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit). When disabled, UPC-E1 decoded data is transmitted as UPC-E1 data, without conversion.
Symbologies 7-19 UCC Coupon Extended Code When enabled, this parameter decodes UPCA bar codes starting with digit ‘5’, EAN-13 bar codes starting with digit ‘99’, and UPCA/EAN-128 Coupon Codes. UPCA, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes. Enable UCC Coupon Extended Code *Disable UCC Coupon Extended Code Use the Decode UPC/EAN Supplemental Redundancy parameter to control autodiscrimination of the EAN128 (right half) of a coupon code.
7-20 WLS 9500 Product Reference Guide Code 128 Enable/Disable Code 128 To enable or disable Code 128, scan the appropriate bar code below. *Enable Code 128 Disable Code 128 Enable/Disable UCC/EAN-128 To enable or disable UCC/EAN-128, scan the appropriate bar code below.
Symbologies 7-21 Enable/Disable ISBT 128 ISBT 128 is a variant of Code 128 used in the blood bank industry. Scan the appropriate bar code below to enable or disable ISBT 128. If necessary, the host must perform concatenation of the ISBT data.
7-22 WLS 9500 Product Reference Guide Code 39 Enable/Disable Code 39 To enable or disable Code 39, scan the appropriate bar code below. *Enable Code 39 Disable Code 39 Enable/Disable Trioptic Code 39 Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39 symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code below.
Symbologies 7-23 Convert Code 39 to Code 32 Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32. Code 39 must be enabled for this parameter to function. . Enable Convert Code 39 to Code 32 *Disable Convert Code 39 to Code 32 Code 32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar codes.
7-24 WLS 9500 Product Reference Guide Set Lengths for Code 39 he length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 39 to any length, one or two discrete lengths, or lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options.
Symbologies 7-25 • Any Length - Select this option to decode Code 39 symbols containing any number of characters within the scanner capability. Code 39 - One Discrete Length Code 39 - Two Discrete Lengths Code 39 - Length Within Range Code 39 - Any Length Code 39 Check Digit Verification When this feature is enabled, the scanner checks the integrity of all Code 39 symbols to verify that the data complies with specified check digit algorithm.
7-26 WLS 9500 Product Reference Guide Transmit Code 39 Check Digit Scan the appropriate bar code below to transmit Code 39 data with or without the check digit. Transmit Code 39 Check Digit (Enable) *Do Not Transmit Code 39 Check Digit (Disable) Code 39 Check Digit Verification must be enabled for this parameter to function.
Symbologies 7-27 Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII, scan the appropriate bar code below. Enable Code 39 Full ASCII *Disable Code 39 Full ASCII Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. Code 39 Full ASCII to Full ASCII Correlation is host-dependent and is described in the ASCII Character Set table for the appropriate interface.
7-28 WLS 9500 Product Reference Guide This feature affects Code 39 only. If selecting Buffer Code 39, we recommend configuring the scanner to decode Code 39 symbology only. Buffer Code 39 (Enable) *Do Not Buffer Code 39 (Disable) While there is data in the transmission buffer, selecting Do Not Buffer Code 39 is not allowed. The buffer holds 200 bytes of information.
Symbologies 7-29 Clear Transmission Buffer To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a dash (minus), and a stop character. • • • The scanner issues a short high/low/high beep. The scanner erases the transmission buffer. No transmission occurs. Clear Buffer Because the Clear Buffer contains only the dash (minus) character, set the Code 39 length to include length 1 before scanning this bar code.
7-30 WLS 9500 Product Reference Guide Overfilling Transmission Buffer The Code 39 buffer holds 200 characters. If the symbol just read results in an overflow of the transmission buffer: • • The scanner indicates that the symbol was rejected by issuing three long, high beeps. No transmission occurs. The data in the buffer is not affected.
Symbologies 7-31 Code 93 Enable/Disable Code 93 To enable or disable Code 93, scan the appropriate bar code below. Enable Code 93 *Disable Code 93 Set Lengths for Code 93 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 93 to any length, one or two discrete lengths, or lengths within a specific range.
7-32 WLS 9500 Product Reference Guide Set Lengths for Code 93 (continued) Code 93 - One Discrete Length Code 93 - Two Discrete Lengths Code 93 - Length Within Range Code 93 - Any Length
Symbologies 7-33 Code 11 Code 11 To enable or disable Code 11, scan the appropriate bar code below. Enable Code 11 *Disable Code 11 Set Lengths for Code 11 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Code 11 to any length, one or two discrete lengths, or lengths within a specific range. • • • • One Discrete Length - Select this option to decode only Code 11 symbols containing a selected length.
7-34 WLS 9500 Product Reference Guide Set Lengths for Code 11 (continued) Code 11 - One Discrete Length Code 11 - Two Discrete Lengths Code 11 - Length Within Range Code 11 - Any Length
Symbologies 7-35 Code 11 Check Digit Verification This feature allows the scanner to check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. The options are to check for one check digit, check for two check digits, or disable the feature. To enable this feature, scan the bar code below corresponding to the number of check digits encoded in your Code 11 symbols.
7-36 WLS 9500 Product Reference Guide Interleaved 2 of 5 (ITF) Enable/Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5 length from the following pages. *Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set Lengths for Interleaved 2 of 5 The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
Symbologies 7-37 Set Lengths for Interleaved 2 of 5 (continued) I 2 of 5 - One Discrete Length I 2 of 5 - Two Discrete Lengths I 2 of 5 - Length Within Range I 2 of 5 - Any Length I 2 of 5 Check Digit Verification When this feature is enabled, the scanner checks the integrity of all I 2 of 5 symbols to verify the data complies with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC) check digit algorithm.
7-38 WLS 9500 Product Reference Guide Transmit I 2 of 5 Check Digit Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit. Transmit I 2 of 5 Check Digit (Enable) *Do Not Transmit I 2 of 5 Check Digit (Disable) Convert I 2 of 5 to EAN-13 Enable this parameter to convert 14-character I 2 of 5 codes to EAN-13, and transmit to the host as EAN-13.
Symbologies 7-39 Discrete 2 of 5 (DTF) Enable/Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5, scan the appropriate bar code below. Enable Discrete 2 of 5 *Disable Discrete 2 of 5 Set Lengths for Discrete 2 of 5 he length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for D 2 of 5 to any length, one or two discrete lengths, or lengths within a specific range.
7-40 WLS 9500 Product Reference Guide Set Lengths for Discrete 2 of 5 (continued) D 2 of 5 - One Discrete Length D 2 of 5 - Two Discrete Lengths D 2 of 5 - Length Within Range D 2 of 5 - Any Length
Symbologies 7-41 Chinese 2 of 5 Enable/Disable Chinese 2 of 5 To enable or disable Chinese 2 of 5, scan the appropriate bar code below.
7-42 WLS 9500 Product Reference Guide Codabar (NW - 7) Enable/Disable Codabar To enable or disable Codabar, scan the appropriate bar code below. Enable Codabar *Disable Codabar Set Lengths for Codabar The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for Codabar to any length, one or two discrete lengths, or lengths within a specific range.
Symbologies 7-43 Set Lengths for Codabar (continued). Codabar - One Discrete Length Codabar - Two Discrete Lengths Codabar - Length Within Range Codabar - Any Length CLSI Editing When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if your host system requires this data format. Symbol length does not include start and stop characters.
7-44 WLS 9500 Product Reference Guide NOTIS Editing When enabled, this parameter strips the start and stop characters from a decoded Codabar symbol. Enable this feature if your host system requires this data format.
Symbologies 7-45 MSI Enable/Disable MSI To enable or disable MSI, scan the appropriate bar code below. Enable MSI *Disable MSI Set Lengths for MSI The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. Set lengths for MSI to any length, one or two discrete lengths, or lengths within a specific range. • • • • One Discrete Length - Select this option to decode only MSI symbols containing a selected length.
7-46 WLS 9500 Product Reference Guide Set Lengths for MSI (continued) MSI - One Discrete Length MSI - Two Discrete Lengths MSI - Length Within Range MSI - Any Length MSI Check Digits With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional. If the MSI codes include two check digits, scan the Two MSI Check Digits bar code to enable verification of the second check digit.
Symbologies 7-47 Transmit MSI Check Digit(s) Scan the appropriate bar code below to transmit MSI data with or without the check digit. Transmit MSI Check Digit(s) (Enable) *Do Not Transmit MSI Check Digit(s) (Disable) MSI Check Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below corresponding to the algorithm used to encode your check digit.
7-48 WLS 9500 Product Reference Guide RSS (Reduced Space Symbology) The variants of RSS are RSS 14, RSS Expanded and RSS Limited. RSS 14 and RSS Expanded include stacked versions. Scan the appropriate bar code below to enable or disable each variant of RSS.
Symbologies 7-49 Convert RSS to UPC/EAN This parameter only applies to RSS-14 and RSS Limited symbols not decoded as part of a Composite symbol. Enable this to strip the leading '010' from RSS-14 and RSS Limited symbols encoding a single zero as the first digit, and report the bar code as EAN-13. For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and reports the bar code as UPC-A.
7-50 WLS 9500 Product Reference Guide Symbology - Specific Security Levels Redundancy Level The scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality.
Symbologies 7-51 Redundancy Level (continued) *Redundancy Level 1 Redundancy Level 2 Redundancy Level 3 Redundancy Level 4
7-52 WLS 9500 Product Reference Guide Security Level The scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so choose only that level of security necessary for any given application.
Symbologies 7-53 Bi-directional Redundancy Enable Bi-directional Redundancy to add security to linear code type security levels. When enabled, a bar code must be successfully scanned in both directions (forward and reverse) before reporting a good decode.
7-54 WLS 9500 Product Reference Guide Symbology - Intercharacter Gap The Code 39 and Codabar symbologies have an intercharacter gap that is customarily quite small. Due to various bar code printing technologies, this gap may grow larger than the maximum size allowed, causing the scanner to be unable to decode the symbol. If this problem is encountered, scan Large Intercharacter Gaps to tolerate out-of-specification bar codes.
8 Miscellaneous Scanner Options Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3 Scanning Sequence Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3 Errors While Scanning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-3 Miscellaneous Parameter Defaults. . . . . . . . . .
8-2 WLS 9500 Product Reference Guide
Miscellaneous Scanner Options 8-3 Introduction This chapter includes commonly used bar codes to customize how data is transmitted to the host device. The scanner ships with the settings shown in the Miscellaneous Scanner Options Default Table on page 8-4 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous scanner defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence.
8-4 WLS 9500 Product Reference Guide Miscellaneous Parameter Defaults Table 8-1 lists the defaults for miscellaneous scanner options parameters. If you wish to change any option, scan the appropriate bar code(s) provided in the Miscellaneous Scanner Parameters section beginning on page 8-5. See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters. Table 8-1.
Miscellaneous Scanner Options 8-5 Miscellaneous Scanner Parameters Transmit Code ID Character A Code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character.
8-6 WLS 9500 Product Reference Guide Prefix/Suffix Values (continued) Scan Prefix Scan Suffix Scan Data Transmission Format To change the scan data format, scan Scan Options and one of the following four bar codes corresponding to the desired format: • • • • Data As Is . Scan Enter on page 8-7 to complete the change. To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 8-5.
Miscellaneous Scanner Options 8-7 Scan Data Transmission Format (continued) Scan Options *Data As Is Enter Data Format Cancel
8-8 WLS 9500 Product Reference Guide FN1 Substitution Values The Wedge and USB HID Keyboard hosts support an FN1 substitution feature. When enabled any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key). To select an FN1 substitution value via bar code menus: 1. Scan the bar code below. *Set FN1 Substitution Value 2.
Miscellaneous Scanner Options 8-9
8-10 WLS 9500 Product Reference Guide
A Standard Default Parameters Table A-1. Standard Default Parameters Table Parameter Default Page Number Set Default Parameter Restore Defaults 4-5 Beeper Tone Medium 4-6 Beeper Volume High 4-6 Power Mode Continuous On 4-7 Scan Pattern Multi-line Always Raster 4-7 Scan Line Width Full Width 4-8 Laser On Time 3.
A-2 WLS 9500 Product Reference Guide Table A-1.
Standard Default Parameters A-3 Table A-1.
A-4 WLS 9500 Product Reference Guide Table A-1.
Standard Default Parameters A-5 Table A-1.
A-6 WLS 9500 Product Reference Guide
B Sample Bar Codes Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UPC/EAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UPC-A, 100% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EAN-13, 100% . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B-2 WLS 9500 Product Reference Guide
Sample Bar Codes B-3 Code 39 123ABC UPC/EAN UPC-A, 100% 0 12345 67890 5 EAN-13, 100% 3 456789 012340 Code 128 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
B-4 WLS 9500 Product Reference Guide Interleaved 2 of 5 1234567890123 RSS RSS variants must be enabled to read the bar codes below (see RSS (Reduced Space Symbology) on page 7-48).
Sample Bar Codes RSS-14 55432198673467 (RSS-14 Truncated) 90876523412674 (RSS-14 Stacked) 78123465709811 (RSS-14 Stacked Omni-Directional) B-5
B-6 WLS 9500 Product Reference Guide
C Numeric Bar Codes Numeric Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3 Cancel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-2 WLS 9500 Product Reference Guide
Numeric Bar Codes Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
C-4 WLS 9500 Product Reference Guide Numeric Bar Codes For parameters requiring specific numeric values, scan the appropriately numbered bar code(s). 6 7 8 9 Cancel To correct an error or change a selection, scan the bar code below.
D ASCII Character Sets Table D-1.
D-2 WLS 9500 Product Reference Guide Table D-1.
ASCII Character Sets D-3 Table D-1. ASCII Value Standard Default Parameters Table (Continued) ASCII Value Full ASCII Code 39 Encode Character Keystroke 1040 /H ( 1041 /I ) 1042 /J * 1043 /K + 1044 /L , 1045 - - 1046 . .
D-4 WLS 9500 Product Reference Guide Table D-1.
ASCII Character Sets D-5 Table D-1.
D-6 WLS 9500 Product Reference Guide Table D-1. ASCII Value Standard Default Parameters Table (Continued) ASCII Value Full ASCII Code 39 Encode Character Keystroke 1124 %Q I 1125 %R } 1126 %S ~ The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent. Table D-2.
ASCII Character Sets D-7 Table D-2. ALT Key Standard Default Tables (Continued) ALT Keys Keystroke 2089 ALT Y 2090 ALT Z Table D-3. Misc. Key Standard Default Table Misc. Key Keystroke 3001 PA 1 3002 PA 2 3003 CMD 1 3004 CMD 2 3005 CMD 3 3006 CMD 4 3007 CMD 5 3008 CMD 6 3009 CMD 7 3010 CMD 8 3011 CMD 9 3012 CMD 10 3013 CMD 11 3014 CMD 12 3015 CMD 13 3016 CMD 14 Table D-4.
D-8 WLS 9500 Product Reference Guide Table D-4. GUI Shift Keys (Continued) 3056 GUI 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3087 GUI W 3088 GUI X 3089 GUI Y 3090 GUI Z Table D-5.
ASCII Character Sets D-9 Table D-5. PF Key Standard Default Table (Continued) PF Keys Keystroke 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010 PF 10 4011 PF 11 4012 PF 12 4013 PF 13 4014 PF 14 4015 PF 15 4016 PF 16 Table D-6.
D-10 WLS 9500 Product Reference Guide Table D-6. F key Standard Default Table (Continued) F Keys Keystroke 5020 F 20 5021 F 21 5022 F 22 5023 F 23 5024 F 24 Table D-7. Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 * 6043 + 6044 Undefined 6045 - 6046 . 6047 / 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Table D-8.
ASCII Character Sets D-11 Table D-8.
D-12 WLS 9500 Product Reference Guide
E Programming Reference Symbol Code Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3 AIM Code Identifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E-2 WLS 9500 Product Reference Guide
Programming Reference E-3 Symbol Code Identifiers Table E-1.
E-4 WLS 9500 Product Reference Guide AIM Code Identifiers Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character (ASCII 93) c = Code Character (see Table E-2) m= Modifier Character (see Table E-3) Table E-2.
Programming Reference E-5 Table E-3. Modifier Characters (Continued) Code Type Code 128 Option Value Option 0 Standard data packet, no Function code 1 in first symbol position. 1 Function code 1 in first symbol character position. 2 Function code 1 in second symbol character position. Example: A Code (EAN) 128 bar code with Function 1 character FNC1 in the first position, AIMID is transmitted as ]C1AIMID I 2 of 5 0 No check digit processing. 1 Reader has validated check digit.
E-6 WLS 9500 Product Reference Guide
Index A aiming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5 ASCII values keyboard wedge . . . . . . . . . . . . . . . . . . 5-13 standard defaults . . . . . . . . . . . . . . . . . . . D-1 USB . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-12 assembling the stand . . . . . . . . . . . . . . . . . . . 2-8 B bar code defaults all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 keyboard wedge . . . . . . . . . . . . . . . . . . . 5-4 miscellaneous . . . . . . . .
IN-2 WLS 9500 Product Reference Guide code 39 transmit check digit . . . . 7-26 code 39, enable/disable . . . . . . . . 7-22 code 93 lengths . . . . . . . . . . . . . . 7-31 code 93, enable/disable . . . . . . . . 7-31 convert UPC-E to UPC-A . . . . . . 7-17 convert UPC-E1 to UPC-A . . . . . 7-18 discrete 2 of 5 lengths . . . . . . . . . 7-39 discrete 2 of 5, enable/disable . . . 7-39 EAN-13/EAN-8, enable/disable . 7-10 EAN-8/JAN-8 extend . . . . . . . . . 7-18 I 2 of 5 check digit verification . .
Index IN-3 N notational conventions . . . . . . . . . . . . . . . . . 2-xiii NW - 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-42 standard default parameters . . . . . . . . . . . . . . D-1 symbologies defaults . . . . . . . . . . . . . . . . . . . 7-6 T P parameter defaults all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 keyboard wedge . . . . . . . . . . . . . . . . . . . 5-4 miscellaneous . . . . . . . . . . . . . . . . . . . . . 8-4 symbologies . . . . . . . . . .