Industrial Scanner Product Reference Guide
WLS 8400 Product Reference Guide
6-6
RS-232 Host Parameters
Various RS-232 host types are set up with their own parameter default settings. Selecting
the host type sets the parameter defaults as listed in Table 6-2.
Table 6-2. Terminal Specific RS-232
Parameter
Standard
RS-232
(Default) ICL
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B Olivetti Omron
OPOS/
JPOS Fujitsu
Transmit
Code ID
No Yes Ye s Yes Yes Yes Yes Yes
Data
Transmission
Format
Data as is Data/
Suffix
Data/
Suffix
Data/
Suffix
Prefix/
Data/
Suffix
Data/
Suffix
Data/
Suffix
Data/
Suffix
Suffix
CR/LF
(7013)
CR (1013) CR (1013) CR (1013) ETX
(1002)
CR (1013) CR (1013) CR (1013)
Baud Rate 9600 9600 9600 9600 9600 9600 9600 9600
Parity None Even Odd Odd Even None Odd None
Hardware
Hand-
shaking
None RTS/CTS
Option 3
RTS/CTS
Option 3
RTS/CTS
Option 3
None None RTS/CTS
Option 3
None
Software
Hand-
shaking
None None None None Ack/Nak None None None
Serial
Response
Time-out
2 Sec. 9.9 Sec. 30.0 Sec. 30.0 Sec. 9.9 Sec. 9.9 Sec. 30.0 Sec. 2 Sec.
Stop Bit
Select
One OneOneOneOneOneOneOne
ASCII
Format
8-Bit 8-Bit 8-Bit 8-Bit 7-Bit 8-Bit 8-Bit 8-Bit
Beep On
<BEL>
Disable Disable Disable Disable Disable Disable Disable Disable
RTS Line
State
Low High Low Low = No
data to
send
Low High Low = No
data to
send
Low
Prefix
None None None None STX
(1003)
None None None