Operating instructions
SoftCare Evo - Type SE10 3-20
Pneumatic system
1 = Filter pressure
regulator
2 = Pressure regulators
Chapter 3 - Structure and function
The main connection for the customer supplied
compressed air is located a the filter pressure
regulator (1a). The compressed air supply is con-
trolled by a ball valve (1b).
Only oil-free compressed air is permitted.
The filter pressure regulator cleans the compressed
air from destructive particles and regulates the com-
pressed air which is provided by the customer to the
main pressure of approx. 6 bar.
Besides the main pressure the system is using re-
duced air pressure for several tasks. These are ad-
justed to the required value by additional pressure
regulators (see chapter 6.1. for setting and pressure
values).
The pneumatic valves are used to control all pneu-
matic components and devices.
Fig. 3-21: Manual operation switches
There is a risk of injury if the manual operation
switches (3) are in position 1. Pneumatic units
may suddenly be moved.
Switch manual operation switches (3) always in
position 0 during automatic operation. No indi-
viduals close to the device when the according
valve is controlled manually.
Fig. 3-19: Filter pressure
regulator
Fig. 3-20: Pneumatic system