Operating instructions
28
48
Mechanical and electrical design
0301
Relays
The FL model employs seven relays. The relays
control:
• the wash windings of the wash motor
• the distribution windings of the wash motor
• the extraction motor
• the drain cycle
• the restart after a programmed stop
• the switching back to low speed extraction if too
high unbalance is indicated.
Construction
The body of the relay holding the stationary
contacts is made of current-resistant plastic. A
solenoid and a contact bank hold the moving
contacts. The contacts are spring-loaded to assure
the correct contact pressure.
The relay is constructed for continuous operation,
whether mounted horizontally or vertically.
Screw-type terminals provide perfect connections
even when one or two wires have different
diameters.
Operation
When the solenoid is energized, the two halves of
the magnet core are drawn together, pulling down
the moving contacts, thus making or breaking the
circuit. When the current cuts out, springs force
the contact bank into its original position, thus
closing or opening the circuits.
Trouble shooting
If the relay fails to operate despite power to the
coil, turn off the power and check the solenoid by
measuring the resistance across the terminals (1).
If the relay hums when power is applied, this
indicates either a break in the insulator holding the
moving contacts at the axle where it holds the top
half of core (3) or a rusty core (4), which can be
cleaned.
Make sure that the moving contact assembly
moves freely. Always replace burnt or pitted
contacts (2) ... do not reuse contacts.
Fig.
48