Operating instructions

24
Main wash
The main wash lasts for approximately 8 minutes
and begins by filling with hot water and dispensing
detergent from compartment 2 (peg no. 8 in rib C
cut away).
The programmer stops the card at peg no. 8 until
the water level is reached.
Rib Q is cut away for the entire main wash to
ensure that the water level is maintained during
the entire wash procedure. The running time once
the required level has been reached is 6 minutes
(peg nos. 8-23 removed from rib Q).
The main wash is concluded with Drain for one
minute (peg nos. 24 and 25 in rib D removed).
Rinse cycles 1-3
Rinse cycles 1-3 each last for approximately 2
minutes and are identical. The following descibes
rinse cycle 1. The rinse cycle begins with Filling
with cold water to high level (peg nos. 26-29 in ribs
N and Q are cut away).
The programmer stops the card at peg 26 until the
water level is reached. The running time once the
water level is reached is 2 minutes.
The rinse cycle is concluded with Drain for 1.5
minutes and with extraction for the last 30 seconds
(peg nos. 30-32 in rib K and peg no. 32 in rib H
removed).
Rib K must always be programmed parallel with rib
H to achieve the extraction cycle. SInce extraction
must not be operated with the drum filled with
water, rib K (Drain) is programmed 2 pegs earlier
that the extraction cycle to drain the water before
the extraction cycle starts. The machine also has a
level guard to ensure that the extraction cycle
cannot start while there is water in the drum.
Card programming
42
1746
43
1745
A. Detergent, (1)
B. Not used (heating)
C. Detergent, (2)
D. Not used (heating)
E. Extern supply
F. Extern supply
G. Extern supply
H. Extraction
I. Fabric softener, (3)
K. Drain
L. High speed extr.
M. Stop with buzzer
N. High level
O. Cold water
P. Cool down
Q. Hot water
Rinse 1
Extraction
Draining
Filling with water
and fabric
conditioner
Rinse 2
Rinse 3
Draining
Fig.
42
Fig.
43
Filling with water and
detergent
Washing
A. Detergent, (1)
B. Not used (heating)
C. Detergent, (2)
D. Not used (heating)
E. Extern supply
F. Extern supply
G. Extern supply
H. Extraction
I. Fabric softener, (3)
K. Drain
L. High speed extr.
M. Stop with buzzer
N. High level
O. Cold water
P. Cool down
Q. Hot water