Operating instructions
22
I- Flushing softener from compartment 3.
Programmed for 30 seconds together with
water filling. If the water pressure is low,
detergent supply should occur after water
filling. Detergent supply can not be
programmed before water filling. If external
liquid supply is used, signal is given to
terminal 5 at the rear connection block.
K- Drain. Cut for 60 second duration.
L- High speed extraction. Cut together with H if
high speeed is desired. Uncut for low speed
extraction.
M-STOP and buzzer. Programmed if a signal is
desired after completed wash or when it is
desirable to stop in mid-cycle for some
reason.
N- High water level. Will provide low level when
not cut.
O- Cold water filling. Programmed for entire
function period. EXAMPLE: Prewash 2
minutes - cold water programmed for two
minutes.
P- Cool down 3-4°C/min. Programmed directly
after main wash without an intervening drain
period. If external liquid supply is used, P
should be cut for flushing of comp. 2 with
each signal.
Q- Hot water filling. Programmed for entire
function period.
The following must be observed when
programming:
Each peg on the program card equals 30 seconds.
(The time unit can be changed to 60 seconds.) To
ensure reliable operation, make sure that the
entire peg is removed.
The program begins with step 0. Cut the peg
before 0 in the same way as 0 to ensure a correct
program start even though the card may be
pushed to far into the controls.
When programming Filling (rib marked O - cold
water and/or Q - hot water, the program controls
stop and start again when the level check provide
a pulse to indicate that the level has been reached
in the drum.
The last pegs that have been cut away (e.g. peg
12) in a program phase determine which peg is to
be removed in the subsequent stage.
Card programming
38
0341
39
1742
A. Detergent, (1)
B. Not used (heating)
C. Detergent, (2)
D. Not used (heating)
E. Extern supply
F. Extern supply
G. Extern supply
H. Extraction
I. Fabric softener, (3)
K. Drain
L. High speed extr.
M. Stop with buzzer
N. High level
O. Cold water
P. Cool down
Q. Hot water
Rest position
(programmed as row 0)
Fig.
38
Fig.
39