Operating instructions
9
Installation
Steam connection
The steam inlet pipe must be fitted with a manual
cut-off valve in order to facilitate installation and
service operations.
Attach the filter supplied with the machine to the
manual cut-off valve.
Conncection hoses should be of the quality
required according to regulations in the country
of use.
Connections size at filter: DN 15 (1/2'').
Steam pressure required:
• minimum: 50 kPa (0.5 kp/cm
2
) (7 psi)
• maximum: 800 kPa (8 kp/cm
2
) (113 psi)
Check there are no sharp angles or bends in the
connection hose.
Connection of top-mount manifold for
connection of external liquid supplies
Remove the cover and cover support from over
the soap box.
Bend all the way back the metal plate in
compartment 3.
Pull the manifold knobs up and forward.
1. Loosen both knobs so that one side of the
metal fingers underneath can slide under the
top lid of the machine, within the supply box.
2. Fit the supply manifold into the supply box so
that both sides are held securely in places by
the metal fingers.
Note:
If the supply manifold does not fit, turn it
around. You have it in backwards.
2369
21
1333
20
1334
1336
19
18
Fig.
18
Fig.
19
Fig.
20
Fig.
21