Service manual
29
29. Door and door lock
6
Service
Manual
Fig.
5
5
Error codes
The door lock control has three LEDs that show
whether the door lock operates normally or
whether an error has been detected. During
normal operation, the LEDs blink when the drum
is not turning and are off when the drum rotates.
In case of an error, the three LEDs will show the
error condition according to the table below. If an
error disappears, the error code condition
disappears. If the error is still present at the
programme end, the error is automatically
cleared after 5 minutes and the door is unlocked.
LEDs Normal operation
ABC
●●● No error. The drum is not turning
(LEDs blinking)
❍❍❍ No error. The drum is rotating
LEDs Error state
ABC
●●❍ Level guard B2 indicates water in drum
when the door lock is open (input X93
not closed).
❍●● Motor control indicates that motor is
operating when door lock is open
(input X94 not open).
●❍❍ No signal from rotation sensor B3
(frequency input X95 < 0.4 Hz) in spite
of the motor control indicating motor
operation (input X94 open).
❍●❍ No signal from motor control (input
X94 not open) in spite of rotation
sensor B3 indicating motor operation
(frequency input X95 > 0.4 Hz).
●❍● Error in drive circuits for door lock
(output X96) or error in door lock/cable
harness for the door lock.
❍❍● Internal error in the door lock control.
❍ = no lit, ● = lit
LEDs
A B C
Reset button
5184