Operating instructions
46
Repair instructions
Lime deposits or dirt on the membrane can result in the valve not opening
or closing correctly. The valve should therefore be cleaned at regular
intervals, depending on operating conditions and water quality.
Valve does not open or close correctly
• Check that the motor is correctly energised
• Check that the piston rod can move freely
• Check that the membrane is not clogged with deposits
When changing the motor and gear assembly, note the following
cable connections:
Brown cable: 60 Hz
Blue cable: Common
Black cable: 50 Hz
Pre-tensioning the return spring
Remove the valve casing.
1. Turn the return spring so that the arm of the spring bears against the
stop screw.
2. Fit the piston rod so that the slot in which the spring is to engage is
aligned with the casing. Place the valve casing over the return spring
so that the pin on the spring fits into the slot in the piston rod.
3. Turn the casing through one turn clockwise. This will engage the pin
on the spring in the piston rod, tensioning the spring by about 1/4 of a
turn due to the rise of the piston rod.
1605
Mechanical and electrical design
Stop screw
Spring extension
Return spring pin
68
Fig.
68