Operating instructions
39
As a further check, the No-load current with V-belt removed is as follows:
Machine No-load current (amps) at terminals:
model Wash Dist.
8910271347
Ex 7 3.6 3.6 1.9 6.2 6.2 6.6 5.6 6.6 3.9
EX 10
120V 4.7 5.5 2.4 8.9 8.9 11.0 6.4 11.0 6.8
Ex 10
208-240V 3.0 2.6 1.45 5.4 5.4 6.8 3.6 6.8 4.5
Machine Resistance (ohms) between terminals:
model 1-4 2-4 3-4 5-7 6-7 8-9 8-10 9-10
Ex 7 2.6 1.6 3.5 2.6 1.6 4.7 4.7 4.7
EX 10
120V 1.3 0.8 1.7 1.3 0.8 3.4 3.4 3.4
Ex 10
208-240V 4.0 2.7 7.7 4.0 2.7 11.4 11.4 11.4
57
0915
Motor cable connector
Checking the motor windings
At room temperature, the motor windings should have the approximate
resistances as shown below, when measured between the appropriate
connectors in the plug:
Fig.
57
Mechanical and electrical design