Operating instructions

27
39
Mechanical and electrical design
0640
Repair instructions
Overheated motor, motor not running
Wait till motor has cooled down. Motor thermal
protectors are automatically reset after appr.
30 minutes. Restart.
Possible cause of motor protector releasing
repeatedly could be oversensitivity of thermal
protector.
Very noisy motor
Breakdown of bearings - replace bearings or
motor.
Motor running slowly
The motor is probably running on two phases
- measure coils on terminal.
Wash motor only runs at one of the speeds
Check that the quick connection is correctly
connected.
Measure coils at connector, as the fault can
be caused by interruption in one of the coils.
Motor locks
Breakdown of bearings - replace bearing or
motor.
Motor does not turn
Check belt tension.
Tensioning of the V-belt
Belt between the wash motor and extract
motor
- release and adjust backing plate to correct
belt tension according to illustration. Fasten
plate.
Belt between extract motor and drum
- remove screws for the attachment of motor
bridge at extract motor side, lower motor
bridge to correct belt tension according to
illustration and fasten bridge.
5/16 in.
92 lbs. force
180 lbs force
1/4 in.
Fig.
39