Operating instructions

26
Mechanical and electrical design
37
38
0638
0639
Drive motors
Description
Both motors, one for wash and distribution and
one for extraction, are installed on the same
motor bridge. The motors drive the drum and are
mechanically connected to each other by V-belts.
On the EX 22 there is also an electromechanical
clutch. The motors rotate at each others' speed
during the wash speed, distribution speed and
low extraction speed.
During high extraction speed the speed control
on the EX 22 gives a signal to the
electromechanical clutch. This disconnects the
motors from each other mechanically. The wash
motor now rotates at distribution speed and the
extract motor at high speed.
On the EX 12 the power supply to the wash
motor is disconnected by the speed control.
On the motor bridge there are belt tensioning
devices. The extract motor is screwed to a
mobile plate which moves via oblong holes in the
motor bridge. This is used to tension the belt
drive between the motors. It is possible to tilt the
entire motor bridge with the use of the oblong
holes on the wash motor side. This is used to
tension the V-belt up the wash drum.
The motors are equipped with thermal protectors
which are placed in the stator coil. In the case of
overheating in the motors, i.e. if the temperature
exceeds 130°, the protector contacts cut the
power to the motor relays.
Fig.
37