Operating instructions
8
11
12
13
1628
10
Water connection
NOTE
All plumbing must conform to national and
local plumbing codes.
Incoming water lines do not require non-return
valves, as the machine is already fitted with a
siphon breaker. However, all incoming lines must
be fitted with shut-off valves and strainers.
• Water inlets are labelled for hot and cold
water connection.
• Flush the water system thoroughly and check
that the strainer at the machine inlet is fitted
correctly.
• Connect the machine to the water mains with
3/4'’ reinforced rubber hosing not to exceed 6
ft in length. Hang the hosing in a large loop.
Do not use rigid piping.
Drain connection
Connect a 3'’ (75 mm) flexible hose to the drain
outlet of the machine.
The drain house must not have any sharp bends
and must slope from the machine to assure
proper drainage. The outlet must open freely to
the main drains.
Do not reduce the size of the drain connection
from the machine to the waste line.
1252
0626
1641
Installation
Fig.
10
Fig.
11
Fig.
12
Fig.
13