Operating instructions

7:2
438 9163-21/03
2
2275
5
2274
3
2276
4
2272
Codes 91 and 92 are used to store the values for
coin slots 1 and 2. For mechanisms with only one
slot, only code 91 is used.
The values to be stored are the ratio of one coin
to the other, (max 3 digits).
For example: if the coin slots are for a 10 cent
coin and a 50 cent coin. The value 1 should be
stored under code 91, and the value 5 should be
stored under code 92.
•Enter code 91 using the buttons which have
become number keys 9 and 1.
The display will now show 91.
•When entering the actual value: keep the
price-programming button activated (the switch
is located under the top cover at the right front
edge). Enter the value 1 and then release the
button.
•Enter code 92. The display will now show 92.
•Enter the value 5.
•Exit the service program by pressing the
service button again.
Fig.
2
Fig.
3
Fig.
4
Fig.
5
Coin meter