Error code Cause/Action
01E Acknowledgement signal for water level not received within time
allowed.
02E Door status acknowledgement signal not received during program
operation.
03E Door lock acknowledgement signal not received within time
allowed.
06E Water level signal above parameter set, on program start-up.
07E Water level signal above parameter set for safety, during program.
10E Water level signal is above parameter set (10 scale units) after
water discharge.
12E The program control unit cannot read the program EPROM.
13E The program control unit receives no response from the motor
control unit.
14E Water level system not calibrated.
11E Mechanical unbalance always activated.
Fault codes
If the power supply to the machine should be cut
while it is working, the programmer has a
memory which stores the program selected for 8
to 10 minutes.
The machine will restart automatically once the
power supply is restored.
Faults/errors in the program or machine are
indicated by a numerical error code on the
control panel display.
In the case of error codes 01, 02 and 03, an
attempt to restart the machine may be made as
soon as the fault has been remedied.
For the other error codes, a service technician
must be called.
Fault codes
Fig.