Operating instructions

76
Trouble-shooting
2508
2502
If water continues to fill without stopping.
A Check for incorrect programming.
B Check hose attached to level control unit on the
printed circuit board.
C Check inlet valves for dirt underneath the valve
diaphragm. To localize, shut off power. If water
continues to flow, inlet valves have foreign
material in them and should be thoroughly
cleaned.
If water continues to flow without filling
machine.
A Check for fault indication on display (see under
the heading "Service Information").
B Check seating of drain valve.