Operating instructions

61
Press:
0203
0204
0205
0206
Programming
Special cooling valve
Answer YES is there is a separate water valve use
for cooling. If the answer is NO, the standard cold
water inlet is used.
Gentle action
Answer YES if the machine is to operate on gentle
action during cooling. The machine will operate on
normal action if the answer is NO.
Times
Cold water is supplied in stages by the water valve
opening and closing according to a particular
pattern. The time for an opening or closing
sequence is 30 seconds. This time is permanently
programmed and cannot be changed. All that can
be programmed is the ratio between open and
closed valve.
The time the valve i open (ON time) can be
programmed separately between 1 and 15
seconds. The valve is closed during the remaining
time up to 30 seconds. The ON time is
programmed separately within two temperature
ranges: 212-158°F (100-70°C) and 158°F (70°C)
— final temperature.
The rate of temperature reduction is monitored
within the 212-158°F (100-70°C) range. If the ON
time is selected so that the water temperature in
the drum decreases by more than 7°F (4°C)/
minute, the valve is closed so that this value is not
exceeded.
The final temperature can between 77-140°F
(25-60°C) be programmed.
FIg.
116
PROGR.MODE SELECT SEQUENCE COOL DOWN 01
PAUSE WITH BUZZER Y/N N
SEPARATE COOL DOWN VALVE Y/N N
GENTLE ACTION Y/N N
PROGR.MODE SELECT SEQUENCE COOL DOWN 01
SEPARATE COOL DOWN VALVE Y/N N
GENTLE ACTION Y/N N
ON TIME 212-158°F (100-70°C) 000 SEC..
JA
KLAR
ENTER
YES
RED.
NER
RED.
NED
JA
KLAR
ENTER
YES
RED.
NER
Press:
30 sec.
30 sec.
30 sec.
30 sec.
0-15
sec.
0-15
sec.
Fig.
117
Fig.
118
Fig.
119
or
EDIT
DOWN
or
EDIT
DOWN
ON
OFF
ON
OFF
116
117
118
119