Operating instructions
58
Water filling
One or several water valves can be selected.
If you decide to use hot and cold water, both
valves will be open while filling is in progress. The
hot water valve will be automatically closed if the
pre-set temperature is exceeded. The valve will
open again if the temperature drops below the pre-
set value.
If only hot water is chosen, the cold water valve
automatically opens if the programmed
temperature is exceeded. (Entered ini new units
on program memory, edition 2 beginning 91.05.10)
Supply injector
The supply injector valves can be controlled in two
different ways. Select one of the methods for each
activated valve:
• 1. By answering YES to the first five questions,
the respective supply injector valve will be open
all the time water filling is in progress.
* Liquid from tank valid only for machine with
external tanks.
• 2. By stating the times for the last five
questions, the respective supply injector valve
will open for the pre-programmed time. The
valves will start to open when water is filled.
* Reduced speed valid only for FC-macines.
Special programming applies to certain machine
sizes:
EX12
• detergent compartment/signal 2:
flushing with cold water in compartment 2
• detergent compartment/signal 4:
flushing with hot water in compartment 2
EX22
• detergent compartment/signal 2
flushing with cold/hot water in compartment 2
Press:
0193
0194
0195
107
108
109
Programming
FIg.
107
PROGR.MODE SELECT SEQUENCE PREWASH 01
WASHTIME 00 MIN. 00 SEC.
COLD WATER Y/N N
HOT WATER Y/N N
PROGR.MODE SELECT SEQUENCE PREWASH 01
HOT WATER Y/N N
COMP. 1. (LEVEL CONTROLLED) Y/N N
COMP. 2. (LEVEL CONTROLLED) Y/N N
JA
KLAR
ENTER
YES
RED.
NER
RED.
NED
EDIT
DOWN
or
Press:
RED.
NED
Number
keys
KLAR
ENTER
JA
or
EDIT
DOWN
PROGR.MODE SELECT SEQUENCE PREWASH 01
COMP.3. (LEVEL CONTROLLED) Y/N N
DET.1. SIGNAL TIME 0 MIN. 00 SEC.
DET.2. SIGNAL TIME 0 MIN. 00 SEC.
PROGR.MODE SELECT SEQUENCE PREWASH 01
REDUCEED SPEED Y/N N
DET.1. SIGNAL TIME 0 MIN. 00 SEC.
DET.2. SIGNAL TIME 0 MIN. 00 SEC.
*
Press:
JA
KLAR
ENTER
YES
RED.
NER
RED.
NED
EDIT
DOWN
or
PROGR.MODE SELECT SEQUENCE PREWASH 01
LIQUID FROM TANK Y/N N
COMP. 1. (LEVEL CONTROLLED) Y/N N
COMP. 2. (LEVEL CONTROLLED) Y/N N
*
Fig.
108
Fig.
109