Operating instructions

46
Procedure
74
FLUSH
75
76
0163
77
0152
0155
COLD
WATER
LOW
EXTR.
HEAT
START
HOLD/RAPID ADV.
Total time
Program number
Number of
programs run
0158
Extract cycle
For safety reasons, there is no manual button for
the extract cycle. There are two choices if
extracting is required during manual operation:
1. Select one of the standard programs and
fast forward to the "Extract" cycle.
2. Program your own program by draining
and extracting for the required time.
Remember the following when programming: Let
the drain valve be open for at least 30 seconds
before starting the spin cycle and program for
distribution speed during the drain sequence.
Finishing off
Switch off the activated function so that all
control lamps above the controls go out.
Program statistics
By selecting program number 00 and pressing
PROG. INFO, the character display shows
program statistics.
The machine's operating time in hours is
displayed first followed by the number of
programs operated for the different programs.
New programs are brought forward by
repeatedly pressing START/HOLD/
RAPID ADV.
Press PROG. INFO once again to get back to
the normal position.
Fig.
74
Fig.
75
Fig.
76
Fig.
77
Fig.
75
°C/°F
DOOR
LOCK
PROG.
INFO.
DRAIN
CLOSED
MOTOR
HOT
WATER
DRAIN
CLOSED
MOTOR
FLUSH
PROG.
INFO.
DOOR
LOCK
°C/°F