Operating instructions

34
Mechanical and electrical design
In two cases the machine will be halted without indication:
Overvoltage in feed.
Motor and/or motor control overheated.
Motor does not operate when it should
Check the voltage feed to the motor control unit by:
- Disconnecting XM4 (quick connector)
- Using a voltmeter (AC) to measure between pins XM4:1-2.
Correct value = 220 V (208 - 240 V)
- Using a voltmeter (DC) to measure between pins XM6:1-4.
Correct value = 250 - 375 V. If not check fuse. Replace unit.
Motor does not operate or operates at wrong speed
Check against the table below whether the motor is receiving the correct
control code from the speed selector circuit board. Measure at connection
X99:1 - 4 with XM2:1 as reference point.
Speed pin 1 pin 2 pin 3 pin 4
0 Stop 0 V 0 V 0 V 0 V
1 Wash speed, right 0 V 0 V 0 V 24 V
2 Wash speed, left 0 V 0 V 24 V 0 V
3 Distribution 0 V 0 V 24 V 24 V
4 Speed when unbalanced 0 V 24 V 0 V 0 V
5 Not used 0 V 24 V 0 V 24 V
6 Not used 0 V 24 V 24 V 0 V
7 Stop 0 V 24 V 24 V 24 V
8 Extraction 8 (HC) 24 V 0 V 0 V 0 V
9 Extraction 1 (LC) 24 V 0 V 0 V 24 V
10 Extraction 2 (LC) 24 V 0 V 24 V 0 V
11 Extraction 3 (LC) 24 V 0 V 24 V 24 V
12 Extraction 4 (HC) 24 V 24 V 0 V 0 V
13 Extraction 5 (HC) 24 V 24 V 0 V 24 V
14 Extraction 6 (HC) 24 V 24 V 24 V 0 V
15 Extraction 7 (HC) 24 V 24 V 24 V 24 V