Indication Cause
The LED flickers. Motor current is at its limit.
The LED comes on and stays on. Undervoltage in feed to motor control.
The LED flashes for 15 sec and Motor control has halted because
then the machine tries to start of wrong signals in control circuit.
again.
The LED shows double flashes. The machine has been stopped on
account of a fresh fault directly after the
last sequence described.