Operating instructions

32
Mechanical and electrical design
Repair instructions
Overheated motor, motor not running
Wait till motor has cooled down. Motor guards
are automatically reset after 30 minutes.
Restart.
Possible cause of motor guards releasing
repeatedly: short circuiting. In both cases the
motor should be replaced.
Very noisy motor
Breakdown of bearings – replace motor.
Motor locks
Breakdown of bearings – replace motor
Motor does not turn
Check belt tension.
When checking the belt tension or when
changing belt, follow the instructions shown.
NOTE!
Checking the belt tension should always
be a part of the regular maintenance.
2311
A
F
47
Fig.
47
EX12 EX22
F 67 lbs 67 lbs
A
max
12 mm 12 mm
A
min
10 mm 10 mm