Operating instructions

15
Installation
Steam connection (compressed air operated)
The following steam pressure values apply:
min: 10 psi
max: 110 psi
recommended: 25-85 psi
Before they are connected, pipes and hoses should first be flushed out with steam.
Procedure:.
Fit the steam valve.
Fit the steam hose between the steam valve and the machine's steam inlet.
The steam supply line must be fitted with a manual shut-off valve. Fit the filter on the
shut-off valve.
The hose should be of a type corresponding to ISO/1307-1983. Connecting dimension at
the filter: DN 15 (R 1/2''). After it is installed, the hose should hang in a gentle curve.
Fit the compressed air hose (A) between the steam valve and the machine.
Connect the compressed air supply to the machine (B).
To achieve slow opening of the valve, the air pressure should not exceed 50 psi.
2442
29
Fig.
29