Installation
Steam connections (optional steam heating)
Steam pressure required:
minimum 7 PSI
maximum: 110 PSI
recommended: 40-85 PSI
A steam valve for this machine type is fitted
separately in a bracket on the upper rear cover
plate. The steam valve, hose and filter are
supplied with the machine.
Steam-flush all pipes and hoses before
connection.
Installation instructions:
Install rear cover plates.
Install steam valve bracket and valve. The
steam valve must be vertical..
Connect the steam hose between the steam
valve and the steam intake on the machine.
The steam inlet pipe must be fitted with a
manual cut-off valve. Fit the filter supplied to
the manual cut-off valve.
Connect an approved 1/2'' hose between the
steam valve and the filter. The connection
must be vertical or be fitted with a pipe
connector in order to avoid sharp angles in the
hose.
The connection hose must be of type ISO/
1307-1983 or equivalent. Connection size at
filter: DN15 (R 1/2'''). Check there are no
sharp angles or bends in the connection hose.