Operating instructions

7
Fig.
9
Installation
8
9
2500
Fig.
8
2483
Electrical installation
Connect L1, L2 and ground wires according to
the markings of the terminal block. The cable is
to hang in a large loose loop, supported by the
clip of the terminal block.
Although the machines are fitted with a thermal
overload in the motor windings and separate
fuses for the control circuit, a separate circuit
breaker must be installed.
For proper overcurrent protection, check the data
plate at the rear of the machine. Also consult
local electrical code for special requirements.
The machine is equipped with a control circuit
transformer, mounted on the control unit and
connected for 220 volt operation. If your
incoming voltage is below 210 volts move the
wire connection to the 208 volt tab on the
transformer. If it is above 230 volts move the
wire to the 240 volt tab on the transformer.