Instruction Manual
7
Series 5800 5800_IOM_RevB_0413
Flow direction is reversed when used with Cylinder Actuator Failed
BODY PRESSURE-TEMPERATURE RATINGS:
Temperature
(F)
150
FLG
Steel
300
NPT, SWE,
or FLG Steel
150
FLG
St Steel
300
NPT, SWE,
or
FLG St Steel
+32° To 100°F 285 740 275 720
150° 272 710 255 670
175° 266 695 245 645
200° 260 680 235 620
225° 252 673 230 605
250° 245 667 225 590
275° 237 661 220 575
300° 230 655 215 560
325° 222 650 210 548
350° 215 645 205 537
375° 207 640 200 526
400° 200 635 195 515
450° 185 620 182 497
500° 170 605 170 480
550° 155 587 155 465
600° 140 570 140 450
650° 125 550 125 440
700° 110 530 110 435
750° 95 505 95 425
800° 80 410 80 420
Body Pressure — Temperature Ratings conform to ANSI based on body/
flange rating and body material. As the fluid temperature increases, the
maximum allowable internal pressure decreases. Verify maximum pressures
and temperatures prior to selecting body material and body/flange rating.
NOTE: Approaching limits for
continuous use will reduce trim
life. For continuous use, stay
within half of rated maximum.
NOTE ON BEARINGS: PEEK
Bearings should not be used
for temperatures above
450ºF or flowing differential
pressure above 300 PSIG.
TRIM MATERIALS
FLOWING
DIFFERENTIAL
PRESSURE LIMIT
316 Stainless Steel 100 PSID
TFE 100 PSID
PEEK 100 PSID
400 Stainless Steel 200 PSID
Alloy 6 300 PSID
SHUT-OFF (ALLOWABLE SEAT LEAKAGE) CLASSES
Leakage
Class Maximum Seat Leakage
Test
Fluid
Test
Pressure
Relative
Seat
Tightness
Class II 0.5% of rated CV Water 45 to 60 PSI 1
Class III 0.1% of rated CV Water 45 to 60 PSI 5
Class IV** 0.01% of rated CV Water 45 to 60 PSI 50
Class V
0.0005 ml /min/inch
of trim size/ ∆P(PSI)
Water Max Operating ∆P 300,000
Class VI** Class VI about 0.9 ml/min * Air 50 PSI 600,000
* Leakage rate varies by valve size, Refer to the ANSI/FCI Standard
70.2.
**Class IV and V are the ONLY leakage classes available within the
5800 Series.
Pressure ratings are PSIG
For applications below 32° consult factory