User guide
6
2600 Emrick Blvd • Bethlehem, PA 18020 • USA •800-922-0085 • www.warrencontrols.com
DIMENSIONS & WEIGHTS
2-WAY
3-WAY
Valves shown with DL84 Actuator as typical.
For additional actuator information see Series 1800 Product Specification and the
Installation Operation and Maintenance Instructions for the actuator in use.
Pressure ratings are PSIG
For applications below 32º consult factory
Body Pressure-Temperature Ratings:
Temperature
(F)
125 FLG
Iron
250 FLG
Iron
150 FLG
Steel
300 FLG
Steel
150 FLG
St Steel
300 FLG
St Steel
+32° To 100° 175 400 285 740 275 720
150° 175 400 272 710 255 670
175° 170 385 266 695 245 645
200° 165 370 260 680 235 620
225° 155 355 252 673 230 605
250° 150 340 245 667 225 590
275° 145 325 237 661 220 575
300° 140 310 230 655 215 560
325° 130 295 222 650 210 548
350° 125 280 215 645 205 537
375° - 265 207 640 200 526
400° - 250 200 635 195 515
450° - - 185 620 182 497
500° - - 170 605 170 480
550° - - 155 587 155 465
600° - - 140 570 140 450
650° - - 125 550 125 440
700° - - 110 530 110 435
750° - - 95 505 95 425
800° - - 80 410 80 420
Trim Materials
Flowing
Differential
Pressure Limit
316 Stainless Steel 100 PSID
Alloy 6 300 PSID