Specifications

54
Output functions
Select either “Tolerance judgment result output”, “Segment output”, or
“BCD output” depending on the application needs.
Display
Units
Tolerance judgment result output Segment output BCD output
Pin No. Description Function I/O Description Function I/O Description Function I/O
1 COM
Common terminal for I/O circuit
(to be connected to the internal GND)
COM
Common terminal for I/O circuit (to
be connected to the internal GND)
COM
Common terminal for I/O circuit (to
be connected to the internal GND)
2 COM COM COM
3 CEL1_-NG
Tolerance judgment result output
pin (1CH)
O -OVER - over-range O 1X100
BCD output will be made through
the specified channel.
O
4 CEL1_GO O -L10
With the specified channel ranges,
make output from ±10 divisions.
O 2X100 O
5 CEL1_+NG O -L9 O 4X100 O
6 CEL1_NOM
Outputs “L” where counting is possible.
O -L8 O 8X100 O
7 CEL2_-NG
Tolerance judgment result output
pin (2CH)
O -L7 O 1X101 O
8 CEL2_GO O -L6 O 2X101 O
9 CEL2_+NG O -L5 O 4X101 O
10 CEL2_-NOM
Outputs “L” where counting is possible.
O -L4 O 8X101 O
11 CEL3_-NG
Tolerance judgment result output
pin (3CH)
O -L3 O 1X102 O
12 CEL3_-GO O -L2 O 2X102 O
13 CEL3_+NG O -L1 O 4X102 O
14 CEL3_NOM
Outputs “L” where counting is possible.
O L0 O 8X102 O
15 CEL4_-NG
Tolerance judgment result output
pin (4CH)
O +L1 O 1X103 O
16 CEL4_GO O +L2 O 2X103 O
17 CEL4_+NG O +L3 O 4X103 O
18 CEL4_NOM
Outputs “L” where counting is possible.
O +L4 O 8X103 O
19 CEL5_-NG
Tolerance judgment result output
pin (5CH)
O +L5 O 1X104 O
20 CEL5_GO O +L6 O 2X104 O
21 CEL5_+NG O +L7 O 4X104 O
22 CEL5_NOM
Outputs “L” where counting is possible.
O +L8 O 8X104 O
23 CEL6_-NG
Tolerance judgment result output
pin (6CH)
O +L9 O 1X105 O
24 CEL6_GO O +L10 O 2X105 O
25 CEL6_+NG O +OVER + over-range O 4X105 O
26 CEL6_NOM
Outputs “L” where counting is possible.
O NOM (ANG)
Outputs “L” where counting is possible.
O 8X105 O
27 EXTEND
Output “L” while the RS command is
processed.
O EXTEND
Output “L” while the RS command
is processed.
O SIGN
Sign of the counting value
(+=”H”, -=”L”)
O
28 READY Data confirmation signal O READY Data confirmation signal O READY Data confirmation signal O
29 START First CEL identification signal O START First CEL identification signal O START First CEL identification signal O
30 NORMAL Normal signal O NORMAL Normal signal O NORMAL Normal signal O
31 P.SET Preset I P.SET Preset I P.SET Preset I
32 OUTCEL Set the objective CEL of output. I OUTCEL Set the objective CEL of output. I OUTCEL Set the objective CEL of output. I
33 SET1
CEL specification data or segment
range data
I SET1
CEL specification data or segment
range data
I SET1
CEL specification data or segment
range data
I
34 SET2
CEL specification data or segment
range data
I SET2
CEL specification data or segment
range data
I SET2
CEL specification data or segment
range data
I
35 SET3
CEL specification data or segment
range data
I SET3
CEL specification data or segment
range data
I SET3
CEL specification data or segment
range data
I
36 HOLD Hold/Peak clear I HOLD Hold/Peak clear I HOLD Hold/Peak clear I
Input / output specifications
1) Compatible plug: 02ADB440 (with cover)
2) Pin assignment
18
1
36
19
Socket: 10236-52A2 (3M) equivalent
EV Counter
DIN size (144 x 72mm) assembly-type unit for multi-gage systems