Specifications
51
Display
Units
FEATURES
144
6.5
4.5
4
4
136
6
72
5
5
161
16
16
139
4
4
64
Tie block
Mounting
fixture
EV Counter
DIN size (144 x 72mm) assembly-type unit for multi-gage systems
FEATURES
• Able to connect up to 10 EV counters to one personal computer using the RS link function to facilitate the configuration of a multi-point
measurement system comprising a maximum of 60 gages.
•
A range of output modes to choose from; I/O output for tolerance judgment and segment output, BCD data output and RS-232 output are available.
SPECIFICATIONS
Order No. 542-063 542-067 542-064
Model No. EV-16P EV-16Z EV-16D
Number of gage inputs 6
Maximum input frequency
1.25MHz (differential square-wave): Max counting Speed: 5MHz Depends on the gage head connected
Resolution 0.0005mm, 0.001mm, 0.005mm, 0.01mm Depends on the gage head connected
LED indication Parameter indication: 8, Error indication: 1
Error indication Overspeed, gage error
Available external display D-EV display unit (optional)
No. of input switches 4
Input switch functions Measurement mode switching, parameter setting
Interface
RS-232C
Measurement data and control signal, Conform to EIA RS-232C standard, Home position: DTE (Data Terminal Equipment), use a cross-type cable.
RS Link
Max. No. of connectable counters: 10 (6: EH counter is mixed.), Max. total length of RS link cable: 10m, Data transfer time: 1sec/60CH at 19200bps
Input /
output
Tolerance judgment 1 to 6-axis (L1, L2, L3), open-collector
BCD output
BCD parallel output (positive logic / negative logic), open-collector
Segment output Turns ON the output terminal corresponding to the measurement value, open-collector
Control output Normal operation signal (NORMAL), open-collector
Control input
Output channel
designation (segment, BCD output modes),
preset,
peak value clear, range switching (segment output mode), data hold,
open-collector or no-voltage contact signal (with/without contact point)
Power supply Terminal block (M3 screws), DC +12 to +24V, 700mA (max.)
Power consumption 8.4W or less
Operating temperature 0°C to 40°C (20%RH to 80%RH, without condensation)
Dimensions W144 x H72 x D156.7mm
Standard accessories Mounting fixture (4 pcs.), tie block (4 pcs.9, screw M4 x 12 (8 pcs.)
Optional accessories
02ADB440: Output plug with cover, 02ADD400: D-EV display unit, 02ADD950: RS Link / SPC connecting cable (0.5m),
936937: RS Link / SPC connecting cable (1m), 965014: RS Link / SPC connecting cable (2m), 02ADD930: Terminal connecting cable,
02ADN460: AC adaptor, AC adaptor connecting cable
Compatible gage head
LGK, LGB (ex. 0.0001mm resolution), LGF
LGF with origin point mark LGD, LGS
Mass (main unit only) 910g 830g
For differential square-wave output gage
heads (6 axes)
For differential square-wave output gage
heads with Origin Point Mark (6 axes)
For Digimatic code output gage heads (6 axes)
Dimensions
Unit: mm
SPECIFICATIONS
542-063 542-067 542-064