Specifications
48
Display
Units
A/B_bit0 1 x 10
0
1 x 10
7
D1 D2 D3 D4 D8
A/B_bit1 1 x 10
0
2 x 10
7
A/B_bit2 1 x 10
0
4 x 10
7
A/B_bit3
D1 D2 D3 D4 D5 D6 D7 D8
Bits 0-3 1 0 6 5 4 3 2 1
SIGN
– 1 2 3 4 5 6 0 1
L
1 x 10
0
8 x 10
7
A/B_bit4
1 x 10
0
2 x 10
0
4 x 10
0
8 x 10
0
SIGN BANK PEAK1 PEAK2
PEAK1 PEAK2
L L
H L
L H
H
NOM
+: H
-: L
MAX
MIN
TIR
BANK1: L
BANK2: H
H
BCD output timing
MIN
2ms
MAX
2ms
MIN
5ms
MIN
5ms
MIN
5ms
SET1
BCDCK
REDY
MIN10msx8=80ms
2) Data format
LSD (Least significant digit)
MSD (Most significant digit)
Data output example
* Negative logic output is possible for SIGN, BANK, PEAK, DATA (PNo.21=1).
Command format Corresponding output Function
GA**CRLF G#**, +01234.567CRLF
Outputs the [Displayed value] through
RS-232C.
CN**CRLF CH**CRLF
Switches the display to the [Current
value].
CX**CRLF CH**CRLF
Switches the display to the [Maximum
value].
CM**CRLF CH**CRLF
Switches the display to the [Minimum
value].
CW**CRLF CH**CRLF
Switches the display to the [TIR
(runout)].
CR**CRLF CH**CRLF Zeroset
CL**CRLF CH**CRLF Clears the peak value.
CP**, +01234567CRLF CH**CRLF Inputs the preset value.
CD**, +01234567CRLF CH**CRLF Inputs tolerance value S1.
CE**, +01234567CRLF CH**CRLF Inputs tolerance value S2.
CF**, +01234567CRLF CH**CRLF Inputs tolerance value S3.
CG**, +01234567CRLF CH**CRLF Inputs tolerance value S4.
CS**CRLF CH**CRLF Cancels the error.
CK**CRLF CH**,$CRLF ($=0 or 1) Checks the HOLD status.
**: denotes a gage channel number between 01 and 99 ("00" means all channels).
#: denotes the type of data [N: Current value, X: Maximum value, M: Minimum value, W: TIR (runout).
CRLF: CR (carriage return), LF (line feed).
Note 1: For presetting and tolerance limit setting, enter each value consisting of a sign and 8 digits of numeric
value without a decimal point.
Note 2: Perform the tolerance limit setting in the order of CD and CG for the case of 3-step tolerance judgment,
and in the order of CD, CE, CF, and CG for the case of 5-step tolerance judgment.
Note 3: The RS communication function will be suspended during key operation (e.g. setting parameters, preset
values, or tolerance limits). It automatically resumes the command and data output operation when the
gage is recovered to such a condition that the counting is possible.
Note 4:
For canceling the counting-standby state, use CS00CRLF (specification of all channels).
4.0V
2.5V
1.0V
–1999 19990
2) Measuring range
Parameter Measuring range (mm) / Resolution (mm)
No.30 1
0μm gage 5μm gage 1μm gage
0 ±19.99(0.01) ±1.999(0.001) ±0.1999(0.0001)
1 ±199.90(0.01) ±19.990(0.01) ±1.9990(0.001)
2 ±1999.00(0.1) ±199.900(0.1) ±19.9900(0.01)
BCD Output
Simultaneously outputs at channels [A] and [B] in groups of 4 bits.
1) Timing chart
RS Link* Function
It is possible to connect a maximum of 10 counter units together to carry a
maximum of 20 channels of multi-point measurement at a time.
For this connection use a dedicated RS link cable; 02ADD950 (0.5m),
936937 (1m) or 965014 (2m) (The maximum total length of RS link cables
permitted for the entire system is 10m.)
* Patent registered (Japan, U.S.), Patent pending (E.U.)
Digimatic Code Output Specifications
Possible to externally output the measured data and connect with a DP-1VR
Digimatic Mini-Processor.
1) Socket to be used
2)
Data output format: A total of 13 digits will be output as follows.
Each digit is represented by a 4-bit binary, and will be output beginning
with the LSB (least significant bit) of the least significant digit in the order
of 20 - 21 - 22 - 23.
RS-232C Communication Functions
Makes it possible not only to log measured values but also make various
remote settings including the zero-setting of a counter, etc.
Simple analog output
Monitoring of output waveforms is possible with an analog recorder connected.
1) Output specification
d1 d2 d3
ALL "F" Measured value
Unit (mm: 0, inch: 1)
Decimal point (0-5) e.g. 0 000000.
1 00000.0
5 00.0000
d4 d5
Sign (+: 0, -: 8)
d6 d7 d8 d9 d10 d11 d12 d13
EH Counter
DIN size (144 x 72mm) assembly-type display unit
Output voltage= 2.5V + [counter value]x[voltage resolution]
(0.75mV)
Range: 1.0-4.0V
Response speed : 10Hz (updating at 5ms)
Accuracy
: ±1% (0.5-4.5V)
Accuracy is rated at 4V level
Load resistance : 300KΩ or more