Specifications
47
Functions
1. Zero-set
Sets the displayed value to 0 at any position
of the spindle.
3-stage
judgement
(GO/±NG)
5-stage
judgement
–NG GO1
Limit1 Limit2 Limit3 Limit4
GO2 GO3 +NG
–NG +NGGO
Upper-limit
tolerance
Lower-limit
tolerance
-!8
-).
4)2¬RUNOUT¬¬-AXIMUM¬¬MINIMUM
3HOWS
THE¬DISPLACEMENT
OF¬RADIUS
AS¬THAT
OF¬DIAMETER¬
2EFERENCE
SURFACE
5. Preset
Presets the display at any value. Counting
begins at the preset value.
12.
Inch/mm switch
Selects mm or inch as the unit of display,
and enables the automatic conversion of
displayed values according to the selected
unit.
11.
Direction switch
Selects the counting direction of (+) or
(-), whichever is convenient with a given
direction of spindle movement.
13.
ABS gage zero set
Sets the absolute origin of an LGD gage
from the counter side. Once set, the
absolute origin will be maintained even
during a power failure or when the counter
is disconnected.
2.
Tolerance judgment indication/output
Sets two (or four) desired tolerances for
three (or five) stages. Judgment results can
be output to an external device.
8.
Double count
Displays a value twice the actual count
value. Allows the direct reading of diameter
for cylindrical objects.
14.
Sum/difference calculation
Enables measurement of thickness or step
height using two gages.
3.
Peak hold/TIR measurement
Allows switching to the measurement mode
for maximum value, minimum value, and
run out value (maximum - minimum), in
addition to the normal measurement mode.
10.
External control
Zero set, preset and display hold can be
controlled from the I/O terminals.
7.
BCD output
The displayed value can be output as one of
I/O signal to a sequence, etc.
15.
Communication via RS-232C interface
RS-232C allows communication with a
personal computer. It allows not only the
reading of measured values but also data
transmission to the counter and remote
operations, such as when changing various
settings.
9.
I/O output
For input/output of external control signals
and tolerance judgment result to/from the
PLCs or other external devices.
6.
Segment output
The function used to divide the specified
range into 21 equal segments and output
where the measured value falls among the
23 segments, including the segments before
and after the divided segments.
4.
Digimatic output
Data can be output to various printers and
statistical processing devices, such as DP-
1VR and MUX-10LF, using Digimatic code
(SPC) output.
27
11.2
137
5.1
137
156.7
144
72
(3.1)
68
138
148.2
AC adapter
(Approx. 10º)
Dimensions
Unit: mm
Standard Accessories
––––––––: Washer (M4, 6 pcs.)
02ADN460: A
C adaptor
––––––––: A
C adaptor connecting cable
––––––––: D
C plug
02ADC304: S
tand
––––––––: R
ubber foot
Optional Accessories
02ADB440: I/O output plug w/ cover
02ADD950: R
S Link connecting cable (0.5m)
936937: R
S Link / SPC connecting cable
(1m)
965014: R
S Link / SPC connecting cable
(2m)